JONES MARTIN ROAD over DOZIER BRANCH
Map
Coordinates:
+33.72709, -82.4623033°43'38" N, 82°27'44" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | JONES MARTIN ROAD over DOZIER BRANCH |
Structure number: | 000000018150080 |
Location: | 4.5 MI SW OF LINCOLNTON |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 24.9 ft. [7.6 m] |
Total length: | 24.9 ft. [7.6 m] |
Roadway width between curbs: | 24.0 ft. [7.3 m] |
Deck width edge-to-edge: | 26.6 ft. [8.1 m] |
Owner: | County Highway Agency [02] |
Year built: | 1950 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Main span material: | Steel [3] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: December 2018
Good/Fair/Poor Condition: | Fair |
Status: | Posted for load [P] |
Average daily traffic: | 600 [as of 2011] |
Truck traffic: | 1% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge with "unknown" foundation that has not been evaluated for scour. [U] |
Sufficiency rating: | 72.1 |
Estimated cost of work: | $147,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
December 2018 | Fair | Fair | Satisfactory | Good | 600 | 72.1 |
December 2016 | Fair | Fair | Satisfactory | Good | 600 | 72.1 |
December 2014 | Fair | Fair | Satisfactory | Good | 600 | 72.1 |
December 2012 | Fair | Fair | Satisfactory | Good | 600 | 72.1 |
December 2010 | Fair | Fair | Satisfactory | Good | 620 | 72.1 |
December 2008 | Fair | Fair | Satisfactory | Good | 620 | 72.1 |
December 2006 | Fair | Fair | Satisfactory | Good | 630 | 72.1 |
December 2004 | Fair | Fair | Satisfactory | Good | 740 | 72.1 |
December 2002 | Fair | Fair | Satisfactory | Good | 740 | 72.1 |
December 2000 | Fair | Satisfactory | Satisfactory | Very Good | 480 | 70.2 |
December 1998 | Fair | Satisfactory | Satisfactory | Good | 470 | 70.2 |
February 1997 | Fair | Satisfactory | Satisfactory | Good | 430 | 70.2 |
March 1995 | Fair | Satisfactory | Satisfactory | Satisfactory | 430 | 69.2 |
June 1993 | Fair | Satisfactory | Satisfactory | Good | 400 | 70.2 |
October 1991 | Fair | Satisfactory | Satisfactory | Satisfactory | 270 | 70.3 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 125 | 0 | 125 | 0 | 0 |
Steel Protective Coating | sq. ft. | 1,124 | 0 | 0 | 1,124 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 668 | 0 | 668 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 54 | 54 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 50 | 30 | 20 | 0 | 0 |