US 19 NBL / SR 400 over CHESTATEE RIVER
Map
Coordinates:
+34.46681, -83.9686134°28'01" N, 83°58'07" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US 19 NBL / SR 400 over CHESTATEE RIVER |
Structure number: | 000000018700160 |
Location: | 4.5 MI S OF DAHLONEGA |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 69.9 ft. [21.3 m] |
Total length: | 414.1 ft. [126.2 m] |
Roadway width between curbs: | 28.9 ft. [8.8 m] |
Deck width edge-to-edge: | 32.2 ft. [9.8 m] |
Owner: | State Highway Agency [01] |
Year built: | 1976 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Number of main spans: | 3 |
Main spans material: | Steel [3] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: January 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 16,980 [as of 2012] |
Truck traffic: | 4% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 62.1 |
Estimated cost of work: | $2,426,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
January 2018 | Fair | Satisfactory | Satisfactory | Satisfactory | 16980 | 62.1 |
December 2015 | Fair | Satisfactory | Satisfactory | Satisfactory | 16980 | 62.1 |
December 2013 | Fair | Satisfactory | Satisfactory | Satisfactory | 16980 | 62.1 |
December 2011 | Fair | Satisfactory | Satisfactory | Satisfactory | 17350 | 62.1 |
December 2009 | Fair | Satisfactory | Satisfactory | Satisfactory | 17660 | 62.1 |
December 2007 | Fair | Satisfactory | Satisfactory | Satisfactory | 17660 | 62.1 |
December 2005 | Fair | Good | Satisfactory | Satisfactory | 16680 | 62.1 |
December 2003 | Fair | Good | Satisfactory | Satisfactory | 16800 | 78.0 |
December 2001 | Fair | Good | Satisfactory | Satisfactory | 15300 | 79.1 |
February 2000 | Fair | Good | Satisfactory | Satisfactory | 5900 | 79.6 |
February 1998 | Fair | Good | Good | Satisfactory | 5900 | 77.6 |
October 1995 | Good | Good | Good | Good | 5900 | 76.4 |
November 1993 | Good | Good | Good | Good | 5520 | 76.5 |
January 1992 | Good | Good | Good | Good | 5520 | 76.5 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 840 | 840 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 8,199 | 8,199 | 0 | 0 | 0 |
Reinforced Concrete Girder/Beam | linear ft. | 816 | 816 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 13,332 | 12,926 | 350 | 56 | 0 |
Substructure |
Reinforced Concrete Column | each | 6 | 2 | 3 | 1 | 0 |
Reinforced Concrete Abutment | linear ft. | 64 | 59 | 5 | 0 | 0 |
Steel Pile | each | 20 | 10 | 10 | 0 | 0 |
Steel Protective Coating | sq. ft. | 2,330 | 2,280 | 0 | 50 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 250 | 232 | 6 | 12 | 0 |
Joints |
Pourable Joint | linear ft. | 261 | 261 | 0 | 0 | 0 |
Bearings |
Movable Bearing | each | 12 | 12 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 24 | 24 | 0 | 0 | 0 |
Fixed Bearing | each | 12 | 12 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 16 | 16 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 828 | 809 | 19 | 0 | 0 |