Share:

CR 161 over LITTLE TOWALIGA RV TRIB

Map

Coordinates:
+33.12249, -84.00417
33°07'21" N, 84°00'15" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:CR 161 over LITTLE TOWALIGA RV TRIB
Structure number:000000020750260
Location:7 MI N OF FORSYTH
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:12.1 ft. [3.7 m]
Total length:24.0 ft. [7.3 m]
Roadway width between curbs:12.1 ft. [3.7 m]
Deck width edge-to-edge:14.1 ft. [4.3 m]
Skew angle:30°
Owner:County Highway Agency [02]
Year built:1940
Year reconstructed:2001
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:2
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Wood or Timber [8]
Wearing surface:Wood or Timber [7]

Latest Available Inspection: September 2016

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:30 [as of 2011]
Truck traffic:1% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Basically intolerable requiring high priority of replacement [2]
Roadway alignment appraisal:Meets minimum tolerable limits to be left in place as is [4]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Scour condition:Bridge with "unknown" foundation that has not been evaluated for scour. [U]
Sufficiency rating:61.4
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$102,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
September 2016FairFairSatisfactoryGood3061.4
September 2014GoodGoodGoodVery Good3062.4
September 2012FairFairGoodVery Good3061.4
September 2010FairFairVery GoodVery Good14058.0
October 2008FairFairVery GoodVery Good14058.0
October 2006FairFairVery GoodVery Good15057.9
October 2004FairFairVery GoodVery Good10067.0
October 2002FairFairVery GoodVery Good10067.0
December 2000PoorPoorVery GoodFair10018.9
December 1998PoorFairSatisfactoryPoor9014.2
August 1996PoorFairSatisfactoryPoor9014.2
October 1994PoorFairSatisfactoryPoor9014.2
January 1993PoorFairSeriousCritical902.0
March 1991PoorFairSeriousSerious902.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.120012000
Steel Protective Coatingsq. ft.500000500
Substructure
Reinforced Concrete Pier Walllinear ft.1414000
Reinforced Concrete Abutmentlinear ft.3333000
Deck
Timber Decksq. ft.3360250860
Wearing Surfacessq. ft.120076404