Share:

THOMPSON POND RD over SWIFT CREEK TRIB.

Map

Coordinates:
+32.24735, -82.43078
32°14'50" N, 82°25'51" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:THOMPSON POND RD over SWIFT CREEK TRIB.
Structure number:000000027900450
Location:2.3 MI N OF VIDALIA
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:20.0 ft. [6.1 m]
Total length:40.0 ft. [12.2 m]
Roadway width between curbs:24.0 ft. [7.3 m]
Deck width edge-to-edge:24.9 ft. [7.6 m]
Owner:County Highway Agency [02]
Year built:1948
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Channel beam [22]
Deck type:Concrete Precast Panels [2]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: August 2017

Good/Fair/Poor Condition:Poor
Status:Posted for load [P]
Average daily traffic:1,980 [as of 2012]
Truck traffic:1% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Poor [4 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge with "unknown" foundation that has not been evaluated for scour. [U]
Sufficiency rating:42.1
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$234,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2017PoorGoodGoodPoor198042.1
August 2015PoorGoodGoodPoor198042.1
July 2013PoorGoodGoodPoor198042.1
July 2011PoorGoodGoodPoor208036.8
July 2009PoorGoodGoodPoor249036.6
July 2007PoorGoodGoodPoor230038.3
July 2005PoorGoodGoodPoor215038.4
August 2003PoorGoodGoodPoor240038.3
October 2001PoorGoodGoodPoor230036.7
September 1999PoorGoodGoodPoor230041.4
August 1997FairGoodGoodFair230053.2
April 1995FairGoodGoodFair190055.8
June 1993FairGoodGoodFair185055.8
June 1991FairGoodGoodFair154055.9

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.320320000
Deck
Reinforced Concrete Top Flangesq. ft.1,00001,00000
Substructure
Reinforced Concrete Abutmentlinear ft.6060000
Timber Pileeach42110
Reinforced Concrete Pier Caplinear ft.2625100
Joints
Pourable Jointlinear ft.2400240