Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:HAWAII BELT RD over WAILUKU STRM
Structure number:001000190409696
Location:0.16MI W/WAINUENUE ST
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:133.9 ft. [40.8 m]
Total length:421.9 ft. [128.6 m]
Roadway width between curbs:27.9 ft. [8.5 m]
Deck width edge-to-edge:38.4 ft. [11.7 m]
Owner:State Highway Agency [01]
Year built:1950
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 18 / H 20 [4]
Number of main spans:5
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: May 2018

Good/Fair/Poor Condition:Poor
Status:Open, no restriction [A]
Average daily traffic:16,600 [as of 2017]
Truck traffic:5% of total traffic
Deck condition:Poor [4 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge is scour critical; bridge foundations determined to be unstable. [3]
Sufficiency rating:42.7
Recommended work:Other structural work, including hydraulic replacements. [38]
Estimated cost of work:$1,970,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2018PoorPoorPoorFair1660042.7
March 2017PoorPoorPoorFair1656542.7
March 2015FairSatisfactorySatisfactoryGood1656583.0
January 2013FairFairSatisfactoryGood1656582.0
March 2011FairFairSatisfactoryGood1656582.0
April 2009FairFairSatisfactoryGood1656582.0
November 2007FairFairSatisfactoryGood1630282.0
September 2005FairFairFairSatisfactory1630271.0
October 2003FairFairFairGood1630271.0
July 2001FairFairFairGood1630271.0
July 1999FairFairFairGood1630269.0
July 1997FairFairFairGood1630266.0
July 1995FairFairFairGood1536666.0
October 1993FairFairFairGood1528066.0
December 1991FairFairFairGood1484666.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,67081060018080
Steel Protective Coatingsq. ft.18,9109,1706,7952,040905
Deck
Reinforced Concrete Decksq. ft.1,9801,49310050337
Substructure
Reinforced Concrete Pier Walllinear ft.120012000
Reinforced Concrete Abutmentlinear ft.802050100
Reinforced Concrete Pile Cap/Footinglinear ft.2061901600
Deck
Open Grid Decksq. ft.9,6813,8315,819301
Steel Protective Coatingsq. ft.19,3627,74211,62000
Joints
Compression Jointlinear ft.72010620
Bearings
Movable Bearingeach2005150
Steel Protective Coatingsq. ft.80020600
Fixed Bearingeach40040
Steel Protective Coatingsq. ft.1600160
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.836432362339
Steel Protective Coatingsq. ft.4,7002,4801,99011219