Share:

IA 5 over COOPER CREEK

Map

Coordinates:
+40.75327, -92.86156
40°45'12" N, 92°51'42" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:IA 5 over COOPER CREEK
Structure number:000000000013930
Location:1.5 mi. N of jct. Iowa #2
Purpose:Carries highway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:59.1 ft. [18.0 m]
Total length:152.9 ft. [46.6 m]
Roadway width between curbs:27.9 ft. [8.5 m]
Deck width edge-to-edge:34.1 ft. [10.4 m]
Owner:State Highway Agency [01]
Year built:1957
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 18 / H 20 [4]
Number of main spans:3
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Low slump Concrete [4]

Latest Available Inspection: June 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:5,900 [as of 2018]
Truck traffic:7% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:51.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2018FairSatisfactorySatisfactoryFair590051.0
June 2016FairSatisfactorySatisfactorySatisfactory560047.2
December 2014FairSatisfactorySatisfactorySatisfactory560047.2
February 2013FairSatisfactorySatisfactorySatisfactory550047.5
February 2011FairSatisfactorySatisfactorySatisfactory550047.5
February 2009FairSatisfactorySatisfactorySatisfactory600045.9
February 2007FairSatisfactorySatisfactorySatisfactory750046.2
October 2005FairSatisfactorySatisfactoryGood750046.2
November 2003FairSatisfactorySatisfactoryFair730036.2
October 2001FairSatisfactorySatisfactoryFair560036.2
November 1999FairSatisfactorySatisfactoryFair550036.2
November 1997FairSatisfactorySatisfactorySatisfactory550046.2
December 1995FairSatisfactorySatisfactorySatisfactory456047.9
March 1993FairSatisfactorySatisfactorySatisfactory419051.2
October 1991FairFairSatisfactorySatisfactory405051.6

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.604596800
Steel Protective Coatingsq. ft.4,3134,13717600
Deck
Reinforced Concrete Decksq. ft.5,2024,47772500
Wearing Surfacessq. ft.4,2843,404860200
Substructure
Reinforced Concrete Columneach44000
Reinforced Concrete Abutmentlinear ft.692730120
Reinforced Concrete Pier Caplinear ft.6060000
Joints
Strip Seal Jointlinear ft.2802350
Compression Jointlinear ft.2802710
Bearings
Movable Bearingeach128004
Fixed Bearingeach40040
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.3062268000