FM over OVER BNSF RR
This bridge is no longer in the current National Bridge Inventory database, and has likely been demolished or abandoned.
Map
Coordinates:
+41.19444, -93.2555641°11'40" N, 93°15'20" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | FM over OVER BNSF RR |
Structure number: | 000000000064090 |
Location: | 0681606 |
Purpose: | Carries highway over railroad |
Route classification: | Minor Collector (Rural) [08] |
Length of largest span: | 21.0 ft. [6.4 m] |
Total length: | 126.0 ft. [38.4 m] |
Roadway width between curbs: | 23.0 ft. [7.0 m] |
Deck width edge-to-edge: | 25.3 ft. [7.7 m] |
Vertical clearance below bridge: | 23.0 ft. [7.0 m] |
Owner: | Railroad [27] |
Year built: | 1946 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 13.5 / H 15 [2] |
Number of main spans: | 7 |
Main spans material: | Wood or timber [7] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Wood or Timber [8] |
Wearing surface: | Wood or Timber [7] |
Latest Available Inspection: October 2008
Good/Fair/Poor Condition: | Poor |
Status: | Open, no restriction [A] |
Average daily traffic: | 45 [as of 2006] |
Truck traffic: | 11% of total traffic |
Deck condition: | Poor [4 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Poor [4 out of 9] |
Structural appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Underclearances appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Roadway alignment appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 49.3 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $510,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
October 2008 | Poor | Poor | Fair | Poor | 45 | 49.3 |
November 1997 | Fair | Satisfactory | Good | Fair | 60 | 65.3 |
March 1991 | Good | Good | Good | Good | 30 | 90.0 |