Share:

FM over SMALL CREEK

Map

Coordinates:
+41.64801, -94.32237
41°38'53" N, 94°19'21" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FM over SMALL CREEK
Structure number:000000000167730
Location:079301503
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:29.9 ft. [9.1 m]
Total length:32.2 ft. [9.8 m]
Roadway width between curbs:20.0 ft. [6.1 m]
Deck width edge-to-edge:20.0 ft. [6.1 m]
Owner:County Highway Agency [02]
Year built:1966
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Main span material:Prestressed concrete [5]
Main span design:Tee beam [04]
Deck type:Concrete Precast Panels [2]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: November 2017

Good/Fair/Poor Condition:Fair
Status:Posted for other load-capacity restriction [R]
Average daily traffic:45 [as of 2016]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:59.3
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
November 2017FairSatisfactorySatisfactoryFair4559.3
December 2015FairSatisfactorySatisfactoryFair7059.3
November 2013FairSatisfactorySatisfactoryFair7059.3
November 2011PoorSatisfactoryGoodPoor7055.7
November 2009PoorSatisfactoryGoodPoor7055.5
January 2008PoorSatisfactoryGoodPoor7055.5
October 2005PoorSatisfactoryGoodPoor10055.7
September 2005FairSatisfactoryGoodFair10071.7
May 2003FairSatisfactoryGoodFair10071.7
July 2001FairSatisfactoryGoodFair10071.7
March 1999FairFairVery GoodFair11057.4
March 1997FairFairVery GoodFair11057.4
April 1995FairSatisfactoryVery GoodFair10070.4
March 1993PoorSatisfactoryVery GoodPoor10055.4
February 1991PoorSatisfactoryVery GoodPoor8555.4