Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SH 51 over BRUNEAU RIVER SLOUGH |
Structure number: | 000000000014550 |
Location: | 0.5 W. BRUNEAU |
Purpose: | Carries highway over waterway |
Route classification: | Minor Arterial (Rural) [06] |
Length of largest span: | 34.1 ft. [10.4 m] |
Total length: | 35.1 ft. [10.7 m] |
Roadway width between curbs: | 25.9 ft. [7.9 m] |
Deck width edge-to-edge: | 28.5 ft. [8.7 m] |
Owner: | State Highway Agency [01] |
Year built: | 1955 |
Historic significance: | Bridge is possibly eligible for the National Register of Historic Places [3] |
Design load: | MS 13.5 / HS 15 [3] |
Main span material: | Concrete [1] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: September 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 1,100 [as of 2016] |
Truck traffic: | 10% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 81.4 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $347,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
September 2018 | Fair | Satisfactory | Good | Good | 1100 | 81.4 |
September 2014 | Fair | Satisfactory | Good | Good | 1100 | 81.4 |
September 2012 | Fair | Satisfactory | Good | Good | 1100 | 81.4 |
September 2011 | Fair | Satisfactory | Good | Good | 1100 | 81.4 |
September 2010 | Fair | Satisfactory | Good | Good | 1100 | 81.4 |
September 2009 | Fair | Satisfactory | Good | Good | 1100 | 81.4 |
September 2008 | Fair | Satisfactory | Good | Good | 1100 | 73.1 |
September 2007 | Fair | Satisfactory | Good | Good | 930 | 74.8 |
September 2006 | Fair | Satisfactory | Good | Good | 930 | 74.8 |
September 2005 | Fair | Satisfactory | Good | Good | 1000 | 74.5 |
September 2004 | Fair | Satisfactory | Good | Good | 1000 | 74.5 |
September 2002 | Fair | Satisfactory | Good | Good | 1100 | 73.1 |
September 2000 | Good | Good | Good | Good | 1200 | 72.7 |
September 1998 | Good | Very Good | Good | Good | 1200 | 73.3 |
September 1996 | Good | Very Good | Good | Good | 820 | 75.7 |
February 1996 | Good | Very Good | Good | Good | 820 | 76.7 |
February 1994 | Good | Very Good | Good | Good | 1110 | 74.7 |
February 1992 | Good | Very Good | Good | Good | 1110 | 74.7 |
February 1991 | Good | Good | Good | Good | 1110 | 78.6 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 246 | 221 | 25 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 1,001 | 751 | 250 | 0 | 0 |
Wearing Surfaces | sq. ft. | 910 | 910 | 0 | 0 | 0 |
Substructure |
Other Material Abutment | linear ft. | 77 | 74 | 3 | 0 | 0 |
Joints |
Pourable Joint | linear ft. | 59 | 0 | 0 | 0 | 59 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 69 | 69 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 386 | 386 | 0 | 0 | 0 |