SH 55 over SNAKE RIVER(MARSING BR)
Map
Coordinates:
+43.54799, -116.8013543°32'53" N, 116°48'05" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SH 55 over SNAKE RIVER(MARSING BR) |
Structure number: | 000000000014670 |
Location: | NEAR MARSING ECL |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 64.0 ft. [19.5 m] |
Total length: | 774.0 ft. [235.9 m] |
Roadway width between curbs: | 27.9 ft. [8.5 m] |
Deck width edge-to-edge: | 38.1 ft. [11.6 m] |
Vertical clearance below bridge: | 13.1 ft. [4.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1955 |
Historic significance: | Bridge is eligible for the National Register of Historic Places [2] |
Design load: | MS 13.5 / HS 15 [3] |
Number of main spans: | 12 |
Main spans material: | Steel continuous [4] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Latest Available Inspection: March 2018
Good/Fair/Poor Condition: | Poor |
Status: | Open, no restriction [A] |
Average daily traffic: | 6,200 [as of 2016] |
Truck traffic: | 11% of total traffic |
Deck condition: | Poor [4 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Poor [4 out of 9] |
Structural appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge is scour critical; bridge foundations determined to be unstable. [3] |
Sufficiency rating: | 30.8 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $12,230,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
March 2018 | Poor | Poor | Satisfactory | Poor | 6200 | 30.8 |
March 2017 | Poor | Poor | Satisfactory | Poor | 6000 | 30.8 |
March 2016 | Poor | Poor | Satisfactory | Poor | 6000 | 30.8 |
March 2015 | Poor | Fair | Satisfactory | Poor | 6000 | 32.8 |
March 2014 | Poor | Fair | Satisfactory | Poor | 6000 | 32.8 |
March 2013 | Poor | Satisfactory | Satisfactory | Serious | 5800 | 11.0 |
March 2012 | Poor | Satisfactory | Satisfactory | Serious | 5800 | 11.0 |
March 2011 | Poor | Satisfactory | Satisfactory | Serious | 6300 | 11.0 |
March 2010 | Poor | Satisfactory | Satisfactory | Serious | 6300 | 11.0 |
March 2009 | Poor | Good | Satisfactory | Serious | 6300 | 11.0 |
March 2008 | Poor | Good | Satisfactory | Serious | 6300 | 11.0 |
March 2007 | Fair | Good | Satisfactory | Fair | 6200 | 44.0 |
February 2006 | Fair | Good | Satisfactory | Fair | 5600 | 44.0 |
February 2005 | Fair | Good | Satisfactory | Fair | 5600 | 44.0 |
February 2004 | Fair | Satisfactory | Satisfactory | Fair | 5600 | 44.0 |
February 2002 | Fair | Satisfactory | Satisfactory | Fair | 5600 | 44.0 |
February 2000 | Fair | Satisfactory | Satisfactory | Fair | 5400 | 44.0 |
February 1998 | Fair | Good | Satisfactory | Fair | 5400 | 44.0 |
September 1996 | Fair | Good | Satisfactory | Fair | 5200 | 44.0 |
September 1994 | Fair | Good | Satisfactory | Fair | 5200 | 44.0 |
September 1992 | Fair | Good | Satisfactory | Fair | 3410 | 47.1 |
September 1991 | Fair | Good | Satisfactory | Fair | 3410 | 47.1 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 3,871 | 3,596 | 195 | 80 | 0 |
Steel Protective Coating | sq. ft. | 44,866 | 0 | 36,066 | 8,000 | 800 |
Deck |
Reinforced Concrete Deck | sq. ft. | 29,407 | 0 | 13,607 | 15,800 | 0 |
Substructure |
Reinforced Concrete Column | each | 121 | 0 | 0 | 121 | 0 |
Reinforced Concrete Abutment | linear ft. | 75 | 60 | 15 | 0 | 0 |
Steel Pile | each | 99 | 0 | 0 | 99 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 384 | 314 | 70 | 0 | 0 |
Joints |
Strip Seal Joint | linear ft. | 132 | 0 | 42 | 80 | 10 |
Pourable Joint | linear ft. | 38 | 38 | 0 | 0 | 0 |
Compression Joint | linear ft. | 19 | 10 | 9 | 0 | 0 |
Bearings |
Movable Bearing | each | 40 | 0 | 0 | 40 | 0 |
Steel Protective Coating | sq. ft. | 80 | 0 | 0 | 0 | 80 |
Fixed Bearing | each | 40 | 0 | 0 | 40 | 0 |
Steel Protective Coating | sq. ft. | 80 | 0 | 0 | 80 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 1,549 | 449 | 1,000 | 100 | 0 |
Steel Protective Coating | sq. ft. | 9,314 | 0 | 0 | 8,300 | 1,014 |