SH 78 over CASTLE CREEK
Map
Coordinates:
+43.05431, -116.2926743°03'16" N, 116°17'34" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SH 78 over CASTLE CREEK |
Structure number: | 000000000015280 |
Location: | 18.8 E. MURPHY |
Purpose: | Carries highway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 29.9 ft. [9.1 m] |
Total length: | 62.0 ft. [18.9 m] |
Roadway width between curbs: | 24.0 ft. [7.3 m] |
Deck width edge-to-edge: | 26.6 ft. [8.1 m] |
Owner: | State Highway Agency [01] |
Year built: | 1955 |
Historic significance: | Bridge is possibly eligible for the National Register of Historic Places [3] |
Design load: | MS 13.5 / HS 15 [3] |
Number of main spans: | 2 |
Main spans material: | Concrete [1] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: August 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 540 [as of 2016] |
Truck traffic: | 35% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge is scour critical; bridge foundations determined to be unstable. [3] |
Sufficiency rating: | 83.1 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $732,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2018 | Fair | Satisfactory | Satisfactory | Satisfactory | 540 | 83.1 |
August 2016 | Fair | Satisfactory | Satisfactory | Fair | 540 | 71.5 |
August 2014 | Fair | Satisfactory | Satisfactory | Fair | 480 | 71.6 |
August 2012 | Fair | Satisfactory | Satisfactory | Fair | 530 | 71.5 |
August 2011 | Fair | Satisfactory | Satisfactory | Fair | 530 | 71.5 |
August 2010 | Fair | Satisfactory | Satisfactory | Fair | 530 | 71.5 |
August 2009 | Fair | Satisfactory | Satisfactory | Fair | 520 | 71.5 |
August 2008 | Fair | Satisfactory | Satisfactory | Fair | 520 | 64.8 |
August 2007 | Fair | Satisfactory | Satisfactory | Fair | 510 | 64.9 |
August 2006 | Fair | Satisfactory | Satisfactory | Fair | 510 | 64.9 |
August 2005 | Fair | Satisfactory | Satisfactory | Fair | 530 | 64.8 |
August 2004 | Fair | Satisfactory | Satisfactory | Fair | 530 | 64.8 |
August 2003 | Fair | Satisfactory | Satisfactory | Fair | 510 | 64.9 |
August 2002 | Fair | Satisfactory | Satisfactory | Fair | 510 | 64.9 |
August 2000 | Fair | Satisfactory | Good | Fair | 450 | 67.1 |
August 1998 | Fair | Satisfactory | Good | Satisfactory | 450 | 78.2 |
August 1996 | Fair | Satisfactory | Good | Good | 370 | 79.3 |
August 1994 | Good | Good | Good | Good | 370 | 79.1 |
March 1992 | Good | Good | Good | Good | 370 | 78.1 |
March 1991 | Good | Good | Good | Good | 370 | 76.1 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 433 | 423 | 10 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 1,647 | 1,597 | 45 | 5 | 0 |
Wearing Surfaces | sq. ft. | 1,482 | 1,482 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 68 | 51 | 13 | 4 | 0 |
Timber Pile | each | 25 | 7 | 18 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 26 | 21 | 3 | 2 | 0 |
Joints |
Compression Joint | linear ft. | 26 | 0 | 0 | 0 | 26 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 125 | 32 | 31 | 62 | 0 |
Steel Protective Coating | sq. ft. | 627 | 534 | 0 | 0 | 93 |