I 90 WBL over SMA 7335;FIFTEENTH ST.IC
Map
Coordinates:
+47.68883, -116.7649747°41'20" N, 116°45'54" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | I 90 WBL over SMA 7335;FIFTEENTH ST.IC |
Structure number: | 000000000016860 |
Location: | IN COEUR D'ALENE;15TH ST. |
Purpose: | Carries highway overpass over highway |
Route classification: | Principal Arterial - Interstate (Urban) [11] |
Length of largest span: | 104.0 ft. [31.7 m] |
Total length: | 104.0 ft. [31.7 m] |
Roadway width between curbs: | 38.1 ft. [11.6 m] |
Deck width edge-to-edge: | 40.0 ft. [12.2 m] |
Vertical clearance below bridge: | 13.1 ft. [4.0 m] |
Skew angle: | 57° |
Owner: | State Highway Agency [01] |
Year built: | 1960 |
Historic significance: | Bridge is eligible for the National Register of Historic Places [2] |
Design load: | MS 18 / HS 20 [5] |
Main span material: | Prestressed concrete [5] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: March 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 15,250 [as of 2016] |
Truck traffic: | 12% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Equal to present minimum criteria [6] |
Underclearances appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 89.4 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $1,270,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
March 2018 | Fair | Satisfactory | Satisfactory | Satisfactory | 15250 | 89.4 |
April 2016 | Fair | Satisfactory | Satisfactory | Satisfactory | 14750 | 84.5 |
April 2014 | Fair | Satisfactory | Satisfactory | Satisfactory | 14000 | 84.5 |
April 2012 | Fair | Satisfactory | Satisfactory | Satisfactory | 12750 | 84.7 |
April 2010 | Fair | Satisfactory | Satisfactory | Satisfactory | 28000 | 83.1 |
April 2008 | Fair | Good | Satisfactory | Satisfactory | 28000 | 75.5 |
April 2006 | Fair | Very Good | Satisfactory | Satisfactory | 28000 | 75.5 |
April 2004 | Fair | Very Good | Satisfactory | Satisfactory | 28000 | 75.5 |
April 2002 | Fair | Very Good | Satisfactory | Satisfactory | 28000 | 72.8 |
April 2000 | Fair | Very Good | Satisfactory | Satisfactory | 24000 | 73.3 |
April 1998 | Good | Very Good | Good | Good | 24000 | 73.3 |
April 1996 | Good | Very Good | Good | Good | 26000 | 74.1 |
April 1994 | Good | Very Good | Good | Good | 26000 | 74.7 |
April 1992 | Good | Very Good | Good | Good | 6340 | 76.6 |
April 1990 | Good | Very Good | Very Good | Good | 6340 | 76.6 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Girder/Beam | linear ft. | 571 | 547 | 24 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 4,155 | 4,140 | 15 | 0 | 0 |
Wearing Surfaces | sq. ft. | 3,952 | 3,952 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 151 | 111 | 26 | 14 | 0 |
Joints |
Pourable Joint | linear ft. | 138 | 138 | 0 | 0 | 0 |
Bearings |
Movable Bearing | each | 6 | 0 | 6 | 0 | 0 |
Steel Protective Coating | sq. ft. | 6 | 0 | 6 | 0 | 0 |
Fixed Bearing | each | 6 | 0 | 6 | 0 | 0 |
Steel Protective Coating | sq. ft. | 6 | 0 | 6 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 202 | 202 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 1,393 | 1,393 | 0 | 0 | 0 |