Share:

STC5711;ST JOE RVR over FALLS CREEK

Map

Coordinates:
+47.32042, -116.29792
47°19'14" N, 116°17'53" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:STC5711;ST JOE RVR over FALLS CREEK
Structure number:000000000020350
Location:15.6 E. ST. MARIES
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:90.9 ft. [27.7 m]
Total length:140.1 ft. [42.7 m]
Roadway width between curbs:32.2 ft. [9.8 m]
Deck width edge-to-edge:35.4 ft. [10.8 m]
Owner:County Highway Agency [02]
Year built:1984
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Box beam or girders - Multiple [05]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: August 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:620 [as of 2015]
Truck traffic:27% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:69.9 tons [63.5 metric tons]
Inventory rating:41.6 tons [37.8 metric tons]
Sufficiency rating:94.7

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
August 201694.7FairSatisfactorySatisfactoryGood-620
August 201494.7GoodGoodGoodGood-620
August 201294.7GoodGoodGoodGood-620
August 201094.7GoodGoodGoodGood-620
August 200894.7GoodGoodGoodGood-620
August 200694.7GoodGoodGoodGood-620
August 200494.7GoodGoodGoodGood-620
August 200294.7GoodGoodGoodGood-620
August 200094.7GoodGoodGoodGood-620
August 199894.7GoodGoodGoodGood-620
August 199694.7GoodGoodGoodGood-600
August 199494.7GoodGoodGoodGood-600
August 199294.7GoodGoodGoodGood-500
August 199092.7GoodGoodGoodGood-500

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Reinforced Concrete Closed Web/Box Girderlinear ft.1411271400
Deck
Reinforced Concrete Decksq. ft.4,9414,9113000
Wearing Surfacessq. ft.4,9413,7061,23500
Substructure
Reinforced Concrete Pier Walllinear ft.4343000
Reinforced Concrete Abutmentlinear ft.7272000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.279279000