Share:

STC5752;PRICHARD S over PRICHARD CR;PRICHARD TRS

Map

Coordinates:
+47.65694, -115.96861
47°39'25" N, 115°58'07" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:STC5752;PRICHARD S over PRICHARD CR;PRICHARD TRS
Structure number:000000000020520
Location:0.1 N. 0.2 E. PRICHARD
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:60.0 ft. [18.3 m]
Total length:62.0 ft. [18.9 m]
Roadway width between curbs:18.4 ft. [5.6 m]
Deck width edge-to-edge:22.3 ft. [6.8 m]
Owner:County Highway Agency [02]
Year built:1950
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:M 13.5 / H 15 [2]
Main span material:Steel [3]
Main span design:Truss - Thru [10]
Deck type:Wood or Timber [8]
Wearing surface:Wood or Timber [7]

Latest Available Inspection: July 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:360 [as of 2015]
Truck traffic:11% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge with "unknown" foundation that has not been evaluated for scour. [U]
Sufficiency rating:50.7
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$795,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
July 2017FairSatisfactorySatisfactoryFair36050.7
July 2015FairGoodSatisfactoryFair36054.4
July 2013FairFairGoodFair36053.4
July 2011FairFairGoodFair42053.4
July 2009FairFairGoodFair42053.4
July 2007FairFairGoodFair42053.4
July 2005FairFairGoodFair42053.4
July 2003FairSatisfactoryGoodFair38064.5
July 2001FairSatisfactoryGoodFair38064.5
July 1999FairSatisfactoryGoodFair28064.5
July 1997FairSatisfactoryGoodFair34064.5
July 1995FairSatisfactoryGoodFair34064.5
July 1993FairSatisfactoryGoodFair28064.5
July 1992FairSatisfactoryGoodFair28064.5
July 1991FairGoodGoodFair28060.5

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Timber Stringerlinear ft.659653600
Steel Trusslinear ft.121932800
Steel Protective Coatingsq. ft.13,15313,01800135
Steel Floor Beamlinear ft.112773500
Steel Protective Coatingsq. ft.37327310000
Steel Gusset Plateeach4804800
Steel Protective Coatingsq. ft.3522640088
Substructure
Reinforced Concrete Abutmentlinear ft.101031700
Deck
Timber Decksq. ft.1,3781,378000
Wearing Surfacessq. ft.1,3781,23814000
Bearings
Fixed Bearingeach40400
Steel Protective Coatingsq. ft.160808