Share:

W. 12TH STREET over FARMERS COOP CANAL

Map

Coordinates:
+43.86472, -116.50306
43°51'53" N, 116°30'11" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:W. 12TH STREET over FARMERS COOP CANAL
Structure number:000000000028065
Location:IN EMMETT; W. 12TH ST
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Collector (Urban) [17]
Length of largest span:24.9 ft. [7.6 m]
Total length:25.9 ft. [7.9 m]
Roadway width between curbs:29.5 ft. [9.0 m]
Deck width edge-to-edge:36.1 ft. [11.0 m]
Owner:City or Municipal Highway Agency [04]
Year built:1965
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:MS 18 / HS 20 [5]
Main span material:Prestressed concrete [5]
Main span design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: October 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:2,000 [as of 2015]
Truck traffic:10% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:79.8
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$660,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2017FairSatisfactoryFairGood200079.8
October 2015FairGoodFairGood320068.6
October 2013FairGoodFairGood320068.6
October 2011FairGoodFairGood220078.7
October 2009FairGoodSatisfactoryGood220089.8
October 2007FairGoodSatisfactorySatisfactory35097.0
October 2005FairGoodSatisfactorySatisfactory35097.0
October 2003FairGoodSatisfactorySatisfactory35097.0
October 2001FairGoodSatisfactorySatisfactory35097.0
October 1999FairGoodSatisfactorySatisfactory35097.0
October 1997FairGoodSatisfactorySatisfactory35097.0
October 1995FairGoodSatisfactorySatisfactory35097.0
October 1993FairGoodSatisfactorySatisfactory35097.0
October 1991FairVery GoodSatisfactorySatisfactory35097.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.2261428220
Deck
Reinforced Concrete Decksq. ft.939939000
Wearing Surfacessq. ft.767767000
Substructure
Reinforced Concrete Abutmentlinear ft.156015600
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.7979000
Steel Protective Coatingsq. ft.368368000