Share:

STC 3833;DEWEY RD over FARMERS COOP CANAL

Map

Coordinates:
+43.88000, -116.69222
43°52'48" N, 116°41'32" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:STC 3833;DEWEY RD over FARMERS COOP CANAL
Structure number:000000000028150
Location:1.0 S. 2.2 W. LETHA
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:30.8 ft. [9.4 m]
Total length:32.2 ft. [9.8 m]
Roadway width between curbs:26.6 ft. [8.1 m]
Deck width edge-to-edge:28.2 ft. [8.6 m]
Skew angle:16°
Owner:County Highway Agency [02]
Year built:1964
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:MS 18 / HS 20 [5]
Main span material:Prestressed concrete [5]
Main span design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: October 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:570 [as of 2015]
Truck traffic:15% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:79.3
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$393,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2017FairGoodSatisfactorySatisfactory57079.3
October 2015FairGoodSatisfactorySatisfactory40080.3
October 2013FairGoodSatisfactorySatisfactory40080.3
October 2011FairGoodSatisfactorySatisfactory40092.8
October 2009FairGoodSatisfactorySatisfactory40092.8
October 2007FairVery GoodSatisfactorySatisfactory40092.8
October 2006FairVery GoodSatisfactorySatisfactory40092.8
October 2005FairVery GoodSatisfactorySatisfactory40092.8
October 2004FairVery GoodSatisfactorySatisfactory40092.8
October 2003PoorVery GoodPoorSatisfactory40065.7
October 2002PoorVery GoodPoorSatisfactory40065.7
October 2000PoorVery GoodPoorSatisfactory40065.7
October 1999PoorVery GoodPoorSatisfactory40065.7
October 1998PoorVery GoodPoorSatisfactory40065.7
October 1997PoorVery GoodPoorSatisfactory40065.7
October 1996PoorVery GoodPoorSatisfactory40065.7
October 1995PoorVery GoodPoorSatisfactory40065.0
October 1994PoorVery GoodPoorSatisfactory40065.0
October 1993PoorVery GoodPoorSatisfactory35065.0
October 1991GoodVery GoodGoodGood35092.1

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.2172019610
Deck
Reinforced Concrete Decksq. ft.902902000
Substructure
Reinforced Concrete Abutmentlinear ft.101010100
Reinforced Concrete Pile Cap/Footinglinear ft.2002000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.8508500
Steel Protective Coatingsq. ft.32718407865