Share:

WOODLAND DRIVE over LITTLE SAND CREEK

Map

Coordinates:
+48.31694, -116.56639
48°19'01" N, 116°33'59" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:WOODLAND DRIVE over LITTLE SAND CREEK
Structure number:000000000030256
Location:3.2 N. 1.0 W. SANDPOINT
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:33.1 ft. [10.1 m]
Total length:37.1 ft. [11.3 m]
Roadway width between curbs:22.0 ft. [6.7 m]
Deck width edge-to-edge:27.9 ft. [8.5 m]
Skew angle:30°
Owner:Other Local Agencies [25]
Year built:1992
Historic significance:Historical significance is not determinable at this time [4]
Design load:M 18 / H 20 [4]
Main span material:Concrete [1]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: August 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:250 [as of 2015]
Truck traffic:10% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge with "unknown" foundation that has not been evaluated for scour. [U]
Sufficiency rating:74.2
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$482,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2017FairSatisfactorySatisfactorySatisfactory25074.2
August 2015FairGoodSatisfactoryGood25074.2
August 2013FairGoodSatisfactoryGood25074.2
August 2011FairGoodSatisfactoryGood25076.7
August 2009FairGoodSatisfactoryGood25076.7
August 2007FairGoodSatisfactoryGood25076.7
August 2005FairGoodSatisfactoryGood25076.7
August 2003FairGoodSatisfactoryGood25076.7
August 2001FairGoodSatisfactoryGood25076.7
August 1999FairGoodSatisfactorySatisfactory25076.7
August 1997FairGoodSatisfactorySatisfactory25076.7
August 1996PoorGoodSatisfactorySerious25033.4

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.2221299300
Deck
Reinforced Concrete Decksq. ft.1,0331,0122100
Substructure
Reinforced Concrete Abutmentlinear ft.56461000
Bearings
Elastomeric Bearingeach1201200
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.75552000