FORD ROAD over LAKE CREEK
Map
Coordinates:
+47.49194, -117.0019447°29'31" N, 117°00'07" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | FORD ROAD over LAKE CREEK |
Structure number: | 000000000030525 |
Location: | 6.3 N. 3.9 W. WORLEY |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 30.8 ft. [9.4 m] |
Total length: | 34.1 ft. [10.4 m] |
Roadway width between curbs: | 16.1 ft. [4.9 m] |
Deck width edge-to-edge: | 16.1 ft. [4.9 m] |
Owner: | Other Local Agencies [25] |
Year built: | 1950 |
Year reconstructed: | 1998 |
Historic significance: | Bridge is possibly eligible for the National Register of Historic Places [3] |
Design load: | MS 18 / HS 20 [5] |
Main span material: | Steel continuous [4] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Corrugated Steel [6] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: August 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 10 [as of 2015] |
Truck traffic: | 5% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge with "unknown" foundation that has not been evaluated for scour. [U] |
Sufficiency rating: | 79.4 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $419,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2017 | Fair | Good | Satisfactory | Satisfactory | 10 | 79.4 |
August 2015 | Fair | Very Good | Good | Satisfactory | 10 | 79.4 |
August 2013 | Fair | Very Good | Good | Satisfactory | 10 | 79.4 |
August 2011 | Fair | Very Good | Good | Satisfactory | 10 | 79.4 |
August 2009 | Fair | Very Good | Good | Satisfactory | 10 | 79.4 |
August 2007 | Fair | Very Good | Good | Satisfactory | 10 | 79.4 |
August 2005 | Fair | Very Good | Good | Satisfactory | 10 | 79.4 |
August 2003 | Fair | Very Good | Good | Satisfactory | 10 | 79.4 |
August 2001 | Fair | Very Good | Very Good | Satisfactory | 10 | 79.4 |
August 1999 | Fair | Excellent | Excellent | Satisfactory | 10 | 79.4 |
August 1998 | Fair | Excellent | Excellent | Satisfactory | 10 | 79.4 |
August 1997 | Poor | Poor | Critical | Poor | 10 | 22.3 |
August 1996 | Poor | Poor | Critical | Poor | 10 | 22.3 |
August 1995 | Poor | Satisfactory | Serious | Poor | 10 | 26.3 |
August 1994 | Fair | Good | Satisfactory | Satisfactory | 10 | 44.8 |
August 1992 | Fair | Good | Good | Satisfactory | 10 | 44.8 |
August 1991 | Fair | Good | Good | Satisfactory | 10 | 44.8 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 128 | 88 | 40 | 0 | 0 |
Steel Protective Coating | sq. ft. | 736 | 536 | 200 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 53 | 48 | 5 | 0 | 0 |
Deck |
Corrugated or Orthotropic Deck | sq. ft. | 549 | 0 | 539 | 10 | 0 |
Wearing Surfaces | sq. ft. | 549 | 0 | 549 | 0 | 0 |
Steel Protective Coating | sq. ft. | 549 | 0 | 539 | 10 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 69 | 69 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 286 | 286 | 0 | 0 | 0 |