Share:

NORTH SIDE ROAD over STC 5752;N.FK.CD'A RIVER

Map

Coordinates:
+47.56972, -116.25250
47°34'11" N, 116°15'09" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:NORTH SIDE ROAD over STC 5752;N.FK.CD'A RIVER
Structure number:000000000030785
Location:0.6 N. ENAVILLE
Purpose:Carries highway over highway and waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:149.9 ft. [45.7 m]
Total length:264.1 ft. [80.5 m]
Roadway width between curbs:18.7 ft. [5.7 m]
Deck width edge-to-edge:19.7 ft. [6.0 m]
Vertical clearance above deck:14.8 ft. [4.5 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Skew angle:10°
Owner:County Highway Agency [02]
Year built:1930
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:M 13.5 / H 15 [2]
Main span material:Steel [3]
Main span design:Truss - Thru [10]
Deck type:Wood or Timber [8]
Wearing surface:Wood or Timber [7]

Latest Available Inspection: June 2017

Good/Fair/Poor Condition:Poor
Status:Posted for load [P]
Average daily traffic:250 [as of 2015]
Truck traffic:5% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Poor [4 out of 9]
Structural appraisal:Basically intolerable requiring high priority of replacement [2]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Underclearances appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge with "unknown" foundation that has not been evaluated for scour. [U]
Sufficiency rating:31.2
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$2,802,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2017PoorFairFairPoor25031.2
June 2016PoorSatisfactorySatisfactoryPoor25031.2
June 2015FairSatisfactorySatisfactoryFair25031.2
June 2014FairSatisfactorySatisfactoryFair25052.4
June 2013FairSatisfactorySatisfactorySatisfactory25062.5
June 2012FairSatisfactorySatisfactorySatisfactory25062.3
June 2011FairSatisfactorySatisfactorySatisfactory25062.3
June 2010FairSatisfactorySatisfactorySatisfactory25062.3
June 2009FairSatisfactorySatisfactorySatisfactory25062.3
June 2008FairSatisfactorySatisfactorySatisfactory25062.3
June 2007FairSatisfactorySatisfactorySatisfactory25062.3
June 2006FairSatisfactorySatisfactorySatisfactory25062.3
June 2005FairSatisfactorySatisfactorySatisfactory25062.3
June 2004FairSatisfactorySatisfactorySatisfactory25062.3
June 2003FairSatisfactorySatisfactorySatisfactory25062.3
June 2002FairSatisfactorySatisfactorySatisfactory25062.3
June 2000FairSatisfactorySatisfactorySatisfactory25062.3
June 1999FairSatisfactorySatisfactorySatisfactory25062.3
June 1998FairSatisfactorySatisfactorySatisfactory25062.3
June 1997FairSatisfactorySatisfactoryFair25052.2
June 1996FairSatisfactorySatisfactoryFair25052.2
June 1995FairSatisfactorySatisfactoryFair25052.2
June 1994PoorSatisfactorySeriousFair25031.2
June 1993PoorSatisfactoryPoorFair25031.2
June 1992PoorSatisfactoryPoorFair25031.2
June 1991PoorGoodPoorFair25031.2

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.226022600
Steel Protective Coatingsq. ft.1,808608300300600
Timber Girder/Beamlinear ft.7486666985
Timber Stringerlinear ft.1,0509985200
Steel Trusslinear ft.299029900
Steel Protective Coatingsq. ft.10,6815,6811,9981,9981,004
Steel Floor Beamlinear ft.1760137390
Steel Protective Coatingsq. ft.1,20006000600
Steel Gusset Plateeach3203200
Steel Protective Coatingsq. ft.51202560256
Substructure
Reinforced Concrete Columneach40400
Reinforced Concrete Pier Walllinear ft.4038200
Reinforced Concrete Abutmentlinear ft.6362100
Reinforced Concrete Pile Cap/Footinglinear ft.33000
Timber Pileeach60420
Reinforced Concrete Pier Caplinear ft.4943033
Timber Pier Caplinear ft.4904900
Deck
Timber Decksq. ft.5,1744,31486000
Wearing Surfacessq. ft.3,1682,69347500
Bearings
Movable Bearingeach20110
Steel Protective Coatingsq. ft.80008
Fixed Bearingeach1001000
Steel Protective Coatingsq. ft.4000040
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.571566050
Steel Protective Coatingsq. ft.1,40801,40800