US 24(EB)/ MAINE S over MISS. R./FRONT ST/BN
Map
Coordinates:
+39.93118, -91.4203439°55'52" N, 91°25'13" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US 24(EB)/ MAINE S over MISS. R./FRONT ST/BN |
Structure number: | 001001900000000 |
Old structure number: | 000001001900621 (from 1992 edition) |
Location: | W EDGE DWNTWN QUINCY |
Purpose: | Carries highway over highway, waterway, and railroad |
Route classification: | Other Principal Arterial (Urban) [14] |
Length of largest span: | 627.7 ft. [191.3 m] |
Total length: | 3511.7 ft. [1070.3 m] |
Roadway width between curbs: | 24.0 ft. [7.3 m] |
Deck width edge-to-edge: | 29.5 ft. [9.0 m] |
Vertical clearance below bridge: | 52.5 ft. [16.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1930 |
Year reconstructed: | 1981 |
Historic significance: | Bridge is eligible for the National Register of Historic Places [2] |
Number of main spans: | 2 |
Main spans material: | Steel continuous [4] |
Main spans design: | Truss - Thru [10] |
Deck type: | Closed Grating [4] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: May 2018
Good/Fair/Poor Condition: | Poor |
Status: | Posted for load [P] |
Average daily traffic: | 8,500 [as of 2017] |
Truck traffic: | 8% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Poor [4 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Underclearances appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Basically intolerable requiring high priority of replacement [2] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 15.1 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $20,166,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2018 | Poor | Fair | Poor | Satisfactory | 8500 | 15.1 |
May 2017 | Poor | Fair | Poor | Satisfactory | 8500 | 15.1 |
April 2016 | Poor | Fair | Poor | Fair | 9350 | 15.1 |
April 2015 | Poor | Satisfactory | Poor | Fair | 9350 | 16.1 |
April 2014 | Poor | Satisfactory | Poor | Fair | 9075 | 16.1 |
April 2012 | Poor | Good | Poor | Fair | 9000 | 21.8 |
April 2011 | Poor | Good | Poor | Fair | 9000 | 20.9 |
April 2009 | Fair | Good | Fair | Fair | 8500 | 47.9 |
April 2007 | Fair | Good | Fair | Fair | 8900 | 49.9 |
April 2005 | Fair | Good | Fair | Fair | 8600 | 49.9 |
March 2003 | Fair | Satisfactory | Fair | Fair | 8600 | 49.9 |
August 2001 | Poor | Satisfactory | Poor | Fair | 8600 | 33.9 |
August 1999 | Fair | Satisfactory | Fair | Fair | 9400 | 49.9 |
July 1997 | Fair | Satisfactory | Fair | Satisfactory | 8500 | 49.9 |
February 1997 | Fair | Satisfactory | Fair | Satisfactory | 7800 | 49.9 |
February 1995 | Fair | Satisfactory | Fair | Satisfactory | 5700 | 49.9 |
March 1993 | Fair | Satisfactory | Fair | Satisfactory | 7600 | 47.9 |
February 1991 | Fair | Satisfactory | Satisfactory | Satisfactory | 7600 | 53.8 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 18,573 | 16,581 | 1,118 | 208 | 666 |
Steel Stringer | linear ft. | 4,316 | 2,003 | 1,990 | 264 | 59 |
Steel Truss | linear ft. | 2,511 | 1,586 | 835 | 81 | 9 |
Steel Floor Beam | linear ft. | 1,289 | 990 | 206 | 86 | 7 |
Steel Gusset Plate | each | 320 | 0 | 224 | 32 | 64 |
Substructure |
Reinforced Concrete Column | each | 106 | 105 | 1 | 0 | 0 |
Reinforced Concrete Pier Wall | linear ft. | 790 | 695 | 28 | 67 | 0 |
Reinforced Concrete Abutment | linear ft. | 59 | 34 | 25 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 709 | 446 | 213 | 24 | 26 |
Deck |
Concrete Filled Grid Deck | sq. ft. | 86,553 | 126 | 82,415 | 4,012 | 0 |
Joints |
Strip Seal Joint | linear ft. | 50 | 50 | 0 | 0 | 0 |
Pourable Joint | linear ft. | 899 | 164 | 715 | 18 | 2 |
Bearings |
Elastomeric Bearing | each | 127 | 0 | 21 | 81 | 25 |
Movable Bearing | each | 4 | 0 | 4 | 0 | 0 |
Fixed Bearing | each | 126 | 3 | 45 | 62 | 16 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 7,015 | 6,464 | 551 | 0 | 0 |