Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I- 94 EDENS over IL 50 (CICERO AVE)
Structure number:016010800000000
Old structure number:000016010803808 (from 1992 edition)
Location:0.5 M N FOSTER
Purpose:Carries highway overpass over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:73.2 ft. [22.3 m]
Total length:295.3 ft. [90.0 m]
Roadway width between curbs:105.0 ft. [32.0 m]
Deck width edge-to-edge:110.9 ft. [33.8 m]
Vertical clearance below bridge:14.1 ft. [4.3 m]
Owner:State Highway Agency [01]
Year built:1948
Year reconstructed:2008
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Other [9]

Latest Available Inspection: March 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:156,300 [as of 2016]
Truck traffic:5% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:80.9 tons [73.5 metric tons]
Inventory rating:48.5 tons [44.1 metric tons]
Sufficiency rating:95.0

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
March 201695.0FairSatisfactorySatisfactorySatisfactory-156300
May 201495.0FairSatisfactorySatisfactorySatisfactory-150800
May 201278.0FairSatisfactorySatisfactorySatisfactory-156000
August 201096.0FairSatisfactorySatisfactorySatisfactory-159500
September 200896.0FairSatisfactorySatisfactorySatisfactory-159200
January 200795.0FairFairSatisfactoryGood-162400
July 200595.0FairFairSatisfactoryGood-166800
June 200495.0FairFairSatisfactoryVery Good-167600
January 200395.0FairFairSatisfactoryVery Good-161100
May 200196.0FairSatisfactorySatisfactoryGood-164800
May 199996.0FairSatisfactorySatisfactoryGood-161600
July 199796.0FairSatisfactoryGoodGood-161000
September 199594.0FairSatisfactoryGoodGoodFO158100
October 199494.0FairSatisfactoryVery GoodGoodFO158100
June 199394.0FairSatisfactoryVery GoodGoodFO149400
February 199294.0GoodGoodVery GoodGoodFO151100

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Closed Web/Box Girderlinear ft.180180000
Steel Girder/Beamlinear ft.1,7721,47329900
Deck
Reinforced Concrete Decksq. ft.32,80030,7816651,3540
Substructure
Reinforced Concrete Columneach3330012
Reinforced Concrete Pier Walllinear ft.798790800
Reinforced Concrete Abutmentlinear ft.222222000
Reinforced Concrete Pier Caplinear ft.1,0201,0000200
Joints
Strip Seal Jointlinear ft.388038800
Bearings
Elastomeric Bearingeach3603600
Movable Bearingeach3600360
Fixed Bearingeach1801800
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.1,26001,210500