Share:

LAKE SHORE DR over FOSTER AVE

Map

Coordinates:
+41.97654, -87.65059
41°58'36" N, 87°39'02" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:LAKE SHORE DR over FOSTER AVE
Structure number:016618200000000
Old structure number:000016618226635 (from 1992 edition)
Location:5200 N. AND 800 W.
Purpose:Carries highway over highway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:68.2 ft. [20.8 m]
Total length:69.2 ft. [21.1 m]
Roadway width between curbs:96.1 ft. [29.3 m]
Deck width edge-to-edge:145.7 ft. [44.4 m]
Vertical clearance above deck:14.1 ft. [4.3 m]
Owner:City or Municipal Highway Agency [04]
Year built:1951
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: November 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:77,800 [as of 2016]
Truck traffic:1% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:48.8 tons [44.4 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:82.8

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
November 201682.8FairGoodSatisfactorySatisfactory-77800
November 201482.9FairGoodSatisfactorySatisfactory-77600
November 201283.1FairGoodSatisfactorySatisfactory-75400
December 201086.2FairGoodSatisfactorySatisfactory-91900
August 200886.5FairGoodSatisfactorySatisfactory-86100
August 200686.7FairGoodSatisfactorySatisfactory-81600
August 200485.9FairGoodSatisfactorySatisfactory-96900
August 200286.3FairGoodSatisfactorySatisfactory-90300
June 200088.9FairGoodSatisfactorySatisfactory-40900
August 199883.9FairGoodSatisfactorySatisfactory-116400
July 199672.7FairFairSatisfactoryFair-85700
July 199470.3FairFairSatisfactoryFair-87200
August 199272.6FairSatisfactorySatisfactoryFair-75200
May 199268.7FairSatisfactorySatisfactoryFair-95200
June 199081.0FairGoodGoodSatisfactory-95200

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Closed Web/Box Girderlinear ft.240024000
Steel Girder/Beamlinear ft.41623118500
Deck
Reinforced Concrete Decksq. ft.10,1933,3664,5717071,549
Substructure
Reinforced Concrete Abutmentlinear ft.292289210
Reinforced Concrete Pier Caplinear ft.29720926620
Joints
Compression Jointlinear ft.1545465350
Bearings
Movable Bearingeach2402400
Fixed Bearingeach2402400
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.6325577500