TR 34 (TH-S14) over CREEK


+41.04924, -89.46654
41°02'57" N, 89°27'60" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.


Name:TR 34 (TH-S14) over CREEK
Structure number:062504200000000
Old structure number:000062504222713 (from 1992 edition)
Location:T12N-R9E-4PM SEC 3
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:11.2 ft. [3.4 m]
Total length:25.9 ft. [7.9 m]
Roadway width between curbs:22.0 ft. [6.7 m]
Deck width edge-to-edge:22.0 ft. [6.7 m]
Owner:Town or Township Highway Agency [03]
Year built:1974
Year reconstructed:1982
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Steel [3]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: August 2015 

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:75 [as of 2014]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank and embankment protection is severely undermined. River control devices have severe damage. Large deposits of debris are in the channel. [4]
Culvert condition:Moderate to major deterioration or disintegration, extensive cracking and leaching or spalls on concrete or masonry walls and slabs. Minor settlement or misalignment. Noticeable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection in one section, significant corrosion or deep pitting. [5]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:44.6 tons [40.5 metric tons]
Inventory rating:26.7 tons [24.3 metric tons]
Sufficiency rating:78.5

Previous Inspections 

DateSuff. RatingConditionCulvert ConditionSD/FOADT
August 201578.5Fair5 out of 10-75
August 201388.5Fair6 out of 10-75
August 201191.5Fair6 out of 10-50
July 200991.5Fair6 out of 10-50
October 200791.5Fair6 out of 10-50
June 200591.5Fair6 out of 10-50
May 200391.5Fair6 out of 10-59
April 200191.5Fair6 out of 10-59
February 199991.5Good7 out of 10-49
April 199791.5Good7 out of 10-49
March 199591.5Good7 out of 10-49
February 199391.5Good7 out of 10-49
June 199191.5Good7 out of 10-49