Share:

SUNRISE ROAD over WILLIAMS CREEK

Map

Coordinates:
+40.10356, -85.48054
40°06'13" N, 85°28'50" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SUNRISE ROAD over WILLIAMS CREEK
Structure number:1800090
Location:00.17 S of CR 600 S
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:47.9 ft. [14.6 m]
Total length:52.5 ft. [16.0 m]
Roadway width between curbs:13.8 ft. [4.2 m]
Deck width edge-to-edge:14.4 ft. [4.4 m]
Owner:County Highway Agency [02]
Year built:1920
Year reconstructed:1999
Historic significance:Bridge is eligible for the National Register of Historic Places [2]
Design load:MS 18 / HS 20 [5]
Main span material:Steel [3]
Main span design:Truss - Thru [10]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: November 2018

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:119 [as of 2018]
Truck traffic:1% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:51.3
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$618,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
November 2018FairSatisfactoryFairFair11951.3
March 2017FairSatisfactoryFairFair11951.3
April 2015FairSatisfactoryFairFair13035.5
September 2013FairGoodFairFair11919.7
September 2011FairVery GoodFairFair10022.9
March 2009FairVery GoodFairFair10022.9
March 2007FairVery GoodFairFair10022.9
March 2005FairVery GoodFairFair10022.9
March 2003FairVery GoodFairFair10022.9
January 2001FairVery GoodFairFair10022.9
January 1999FairVery GoodFairFair10023.9
October 1996PoorPoorImminent FailureSerious10027.2
October 1994PoorFairSeriousSerious10028.9
May 1992PoorFairSeriousSerious10028.9
March 1990PoorFairSeriousSerious10028.9