FUSION RD over BUCK CREEK
Map
Coordinates:
+40.14926, -85.3781940°08'57" N, 85°22'41" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | FUSION RD over BUCK CREEK |
Structure number: | 1800152 |
Location: | 00.10 E of WALNUT St |
Purpose: | Carries highway over waterway |
Route classification: | Minor Arterial (Urban) [16] |
Length of largest span: | 32.5 ft. [9.9 m] |
Total length: | 86.6 ft. [26.4 m] |
Roadway width between curbs: | 28.2 ft. [8.6 m] |
Deck width edge-to-edge: | 31.2 ft. [9.5 m] |
Skew angle: | 30° |
Owner: | County Highway Agency [02] |
Year built: | 1993 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 3 |
Main spans material: | Concrete continuous [2] |
Main spans design: | Slab [01] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: November 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 924 [as of 2018] |
Truck traffic: | 2% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4] |
Sufficiency rating: | 91.4 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
November 2018 | Fair | Satisfactory | Good | Satisfactory | 924 | 91.4 |
March 2017 | Fair | Satisfactory | Good | Satisfactory | 924 | 91.4 |
March 2015 | Fair | Satisfactory | Good | Satisfactory | 924 | 91.4 |
March 2013 | Good | Good | Very Good | Good | 1000 | 91.3 |
March 2011 | Good | Good | Very Good | Good | 1000 | 91.3 |
April 2009 | Good | Good | Very Good | Good | 1000 | 91.3 |
April 2007 | Good | Good | Very Good | Good | 1000 | 91.3 |
April 2005 | Good | Good | Very Good | Good | 1000 | 91.3 |
April 2003 | Good | Very Good | Very Good | Very Good | 1000 | 91.3 |
January 2001 | Good | Very Good | Very Good | Very Good | 1000 | 91.3 |
February 1999 | Good | Very Good | Very Good | Very Good | 1000 | 91.3 |
October 1996 | Good | Very Good | Very Good | Very Good | 1000 | 91.3 |
November 1994 | Good | Very Good | Very Good | Very Good | 1000 | 91.3 |
May 1992 | Poor | Poor | Poor | Serious | 1000 | 10.6 |
March 1990 | Poor | Serious | Poor | Serious | 1000 | 10.6 |