Facts 

Name:CR 3 over BRANCH OF BAUGO CREEK
Structure number:2000182
Location:00.10 S OF CR 26
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:20.0 ft. [6.1 m]
Total length:22.0 ft. [6.7 m]
Roadway width between curbs:21.0 ft. [6.4 m]
Deck width edge-to-edge:21.0 ft. [6.4 m]
Owner:County Highway Agency [02]
Year built:1955
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Concrete [1]
Main span design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: August 2016 

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:830 [as of 2011]
Truck traffic:20% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:44.9 tons [40.8 metric tons]
Inventory rating:33.9 tons [30.8 metric tons]
Sufficiency rating:77.1

Previous Inspections 

DateSuff. RatingConditionCulvert ConditionSD/FOADT
August 201677.1Fair6 out of 10FO830
August 201496.1Fair6 out of 10-830
August 201296.1Fair6 out of 10-830
October 201096.0Fair6 out of 10-830
October 200896.0Good7 out of 10-722
October 200696.8Good7 out of 10-722
September 200499.9Fair6 out of 10-626
July 200299.9Fair6 out of 10-626
May 200099.9Fair6 out of 10-626
August 199899.9Fair6 out of 10-576
May 199699.9Fair6 out of 10-576
September 199499.9Good7 out of 10-576
June 199296.9Good7 out of 10-408
June 199098.8Good7 out of 10-700