Share:

CR 350N over BRANCH OF RAMP RUN

Map

Coordinates:
+39.81222, -86.64861
39°48'44" N, 86°38'55" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:CR 350N over BRANCH OF RAMP RUN
Structure number:3200066
Location:00.00 E OF SR 75
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:62.7 ft. [19.1 m]
Total length:67.9 ft. [20.7 m]
Roadway width between curbs:29.9 ft. [9.1 m]
Deck width edge-to-edge:30.2 ft. [9.2 m]
Skew angle:41°
Owner:County Highway Agency [02]
Year built:1935
Year reconstructed:1970
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Concrete [1]
Main span design:Arch - Deck [11]
Deck type:Not applicable [N]

Latest Available Inspection: June 2016

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:330 [as of 2014]
Truck traffic:6% of total traffic
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Basically intolerable requiring high priority of corrrective action [3]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4]
Operating rating:23.0 tons [20.9 metric tons]
Inventory rating:17.9 tons [16.3 metric tons]
Sufficiency rating:59.8
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$687,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
June 201659.8Fair-FairFairFO330
June 201461.9Fair-FairFair-330
June 201249.8Poor-PoorSatisfactorySD290
October 201049.6Poor-PoorSatisfactorySD290
July 200844.6PoorPoorPoorSatisfactorySD270
August 200663.7Fair-FairSatisfactory-217
August 200463.7Fair-FairSatisfactory-217
August 200273.7Fair-SatisfactorySatisfactory-217
August 200083.3Fair-SatisfactorySatisfactory-115
June 199882.9Fair-SatisfactorySatisfactory-115
May 199682.9Fair-SatisfactorySatisfactory-129
December 199482.9Fair-SatisfactorySatisfactory-129
July 199273.7Fair-SatisfactorySatisfactory-129
June 199067.2FairGoodSatisfactorySatisfactory-200