Share:

BROOKLINE DR over EAST FORK OF MILL CREEK

Map

Coordinates:
+39.75000, -86.53333
39°45'00" N, 86°31'60" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:BROOKLINE DR over EAST FORK OF MILL CREEK
Structure number:3200243
Location:00.00 W OF CLEAR CREEK
Purpose:Carries highway over waterway
Route classification:Local (Urban) [19]
Length of largest span:5.9 ft. [1.8 m]
Total length:32.2 ft. [9.8 m]
Roadway width between curbs:28.9 ft. [8.8 m]
Deck width edge-to-edge:28.9 ft. [8.8 m]
Skew angle:15°
Owner:County Highway Agency [02]
Year built:2004
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:4
Main spans material:Steel [3]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: June 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:70 [as of 2014]
Truck traffic:5% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:44.9 tons [40.8 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Sufficiency rating:100.0

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
June 2016100.0Good7 out of 10-70
June 2014100.0Good7 out of 10-70
June 2012100.0Good7 out of 10-60
October 2010100.0Good7 out of 10-60
August 2008100.0Good8 out of 10-50
August 2006100.0Good8 out of 10-50
October 2004100.0Good8 out of 10-50