Share:

CR 100 SOUTH over TRIMBLE CREEK

Map

Coordinates:
+41.21722, -85.98944
41°13'02" N, 85°59'22" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts

Name:CR 100 SOUTH over TRIMBLE CREEK
Structure number:4300201
Location:00.75 W OF CR 700W
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:15.1 ft. [4.6 m]
Total length:49.5 ft. [15.1 m]
Roadway width between curbs:31.5 ft. [9.6 m]
Deck width edge-to-edge:53.5 ft. [16.3 m]
Owner:County Highway Agency [02]
Year built:1980
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Steel [3]
Main spans design:Culvert [19]
Deck type:Not applicable [N]
Wearing surface:Bituminous [6]

Latest Available Inspection: March 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:275 [as of 2014]
Truck traffic:5% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Operating rating:44.9 tons [40.8 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Sufficiency rating:97.0

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
March 201697.0Fair6 out of 10-275
March 201497.0Fair6 out of 10-275
March 201296.0Fair6 out of 10-275
April 201096.0Fair6 out of 10-275
March 200896.0Good7 out of 10-275
March 200696.0Good7 out of 10-275
April 200495.9Good7 out of 10-275
April 200296.9Good7 out of 10-265
May 200096.9Good7 out of 10-250
April 199896.9Good7 out of 10-250
April 199686.8Good7 out of 10-230
May 199486.8Good7 out of 10-230
June 199278.2Good7 out of 10-230
September 199094.1Good7 out of 10-200