Share:

GRAY ST over SARTOR DITCH

Map

Coordinates:
+39.41972, -86.41389
39°25'11" N, 86°24'50" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:GRAY ST over SARTOR DITCH
Structure number:5500160
Location:00.06 E OF S HOME AVE
Purpose:Carries highway over waterway
Route classification:Local (Urban) [19]
Length of largest span:21.0 ft. [6.4 m]
Total length:23.0 ft. [7.0 m]
Roadway width between curbs:31.8 ft. [9.7 m]
Deck width edge-to-edge:31.8 ft. [9.7 m]
Owner:City or Municipal Highway Agency [04]
Year built:2001
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Concrete [1]
Main span design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: August 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:390 [as of 2014]
Truck traffic:10% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:44.9 tons [40.8 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Sufficiency rating:100.0

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
August 2016100.0Good7 out of 10-390
August 2014100.0Good7 out of 10-390
August 201297.0Good7 out of 10-340
September 201098.0Good7 out of 10-340
March 200898.0Good8 out of 10-320
April 200698.0Good9 out of 10-320
March 200498.0Good9 out of 10-300
May 200298.0Good9 out of 10-300
April 200087.0Fair5 out of 10-300
April 199987.0Fair5 out of 10-300