Pfeiffer Rd over Big Creek
This bridge is no longer in the current National Bridge Inventory database, and has likely been demolished or abandoned.
Map
Coordinates:
+38.03806, -87.8222238°02'17" N, 87°49'20" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | Pfeiffer Rd over Big Creek |
Structure number: | 6500247 |
Location: | 01.08 NW of Boberg Rd |
Purpose: | Carries highway over waterway |
Route classification: | Minor Collector (Rural) [08] |
Length of largest span: | 36.1 ft. [11.0 m] |
Total length: | 104.0 ft. [31.7 m] |
Roadway width between curbs: | 23.6 ft. [7.2 m] |
Deck width edge-to-edge: | 24.3 ft. [7.4 m] |
Skew angle: | 45° |
Owner: | County Highway Agency [02] |
Year built: | 1920 |
Year reconstructed: | 2011 |
Historic significance: | Bridge is eligible for the National Register of Historic Places [2] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 3 |
Main spans material: | Prestressed concrete [5] |
Main spans design: | Box beam or girders - Multiple [05] |
Deck type: | Concrete Precast Panels [2] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: January 2013
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 200 [as of 2010] |
Truck traffic: | 4% of total traffic |
Deck condition: | Very Good [8 out of 9] |
Superstructure condition: | Very Good [8 out of 9] |
Substructure condition: | Very Good [8 out of 9] |
Structural appraisal: | Equal to present desirable criteria [8] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 84.9 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
January 2013 | Good | Very Good | Very Good | Very Good | 200 | 84.9 |
May 2010 | Poor | Fair | Serious | Fair | 200 | 21.1 |
March 2008 | Poor | Fair | Serious | Fair | 175 | 21.2 |
March 2006 | Poor | Fair | Serious | Fair | 175 | 23.4 |
February 2004 | Poor | Fair | Serious | Fair | 175 | 23.4 |
February 2003 | Poor | Fair | Serious | Fair | 175 | 23.4 |
February 2002 | Poor | Fair | Serious | Fair | 175 | 23.4 |
June 2000 | Poor | Fair | Serious | Fair | 175 | 23.7 |
June 1998 | Poor | Fair | Serious | Fair | 175 | 23.4 |
April 1996 | Poor | Fair | Poor | Fair | 175 | 34.2 |
May 1994 | Fair | Fair | Fair | Fair | 100 | 47.1 |
November 1991 | Fair | Fair | Satisfactory | Fair | 100 | 50.4 |
January 1990 | Fair | Fair | Satisfactory | Fair | 100 | 42.8 |