Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:THOMASTOWN RD over STOP RUN
Structure number:7200081
Location:00.50 E FINLEY FIREHOUSE
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:20.0 ft. [6.1 m]
Total length:22.0 ft. [6.7 m]
Roadway width between curbs:20.3 ft. [6.2 m]
Deck width edge-to-edge:21.7 ft. [6.6 m]
Owner:County Highway Agency [02]
Year built:1967
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: October 2015

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:70 [as of 2015]
Truck traffic:5% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:20.9 tons [19.0 metric tons]
Inventory rating:12.0 tons [10.9 metric tons]
Sufficiency rating:59.5
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$400,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
October 201559.5FairSatisfactorySatisfactoryGood-70
October 201359.5FairSatisfactorySatisfactoryGood-60
October 201148.8FairSatisfactorySatisfactoryGoodSD60
September 200948.8FairSatisfactorySatisfactoryGoodSD50
June 200748.8FairSatisfactorySatisfactoryGoodSD50
July 200548.8FairSatisfactorySatisfactoryGoodSD50
April 200350.8FairSatisfactorySatisfactoryGoodFO25
April 200150.8FairSatisfactorySatisfactoryGoodFO25
March 199973.8FairSatisfactorySatisfactoryGood-25
April 199773.8FairSatisfactoryGoodGood-25
March 199573.8GoodGoodGoodGood-25
June 199369.1GoodGoodGoodGood-100
February 199176.9FairSatisfactoryGoodGood-100