Share:

T.1-29 (340) over SOUTH FORK SAPPA CREEK

Map

Coordinates:
+39.29211, -101.54018
39°17'32" N, 101°32'25" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts

Name:T.1-29 (340) over SOUTH FORK SAPPA CREEK
Structure number:000000000910340
Location:3.1S 9.0E OF GOODLAND
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:16.1 ft. [4.9 m]
Total length:33.1 ft. [10.1 m]
Roadway width between curbs:31.5 ft. [9.6 m]
Deck width edge-to-edge:33.1 ft. [10.1 m]
Owner:County Highway Agency [02]
Year built:1973
Historic significance:Historical significance is not determinable at this time [4]
Design load:M 18 / H 20 [4]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]
Wearing surface:Gravel [8]

Latest Available Inspection: May 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:70 [as of 2014]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:43.9 tons [39.9 metric tons]
Inventory rating:26.0 tons [23.6 metric tons]
Sufficiency rating:88.5

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
May 201688.5Good7 out of 10-70
May 201488.5Good7 out of 10-63
May 201288.5Good7 out of 10-63
April 201088.5Good7 out of 10-63
April 200888.5Good7 out of 10-80
May 200688.5Good7 out of 10-35
March 200488.5Good7 out of 10-35
April 200288.5Good7 out of 10-35
June 200088.5Good7 out of 10-35
March 199888.5Good7 out of 10-35
April 199688.2Good8 out of 10-77
September 199397.1Good8 out of 10-77
October 199197.1Good8 out of 10-77