Share:

191ST RD. over STREAM

Map

Coordinates:
+38.80424, -98.74410
38°48'15" N, 98°44'39" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:191ST RD. over STREAM
Structure number:000840669004646
Location:4.5S 2.0W OF BUNKER HILL
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:21.0 ft. [6.4 m]
Total length:42.7 ft. [13.0 m]
Roadway width between curbs:23.6 ft. [7.2 m]
Deck width edge-to-edge:24.0 ft. [7.3 m]
Owner:County Highway Agency [02]
Year built:1954
Historic significance:Historical significance is not determinable at this time [4]
Number of main spans:2
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Wood or Timber [8]
Wearing surface:Wood or Timber [7]

Latest Available Inspection: April 2017

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:25 [as of 2008]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4]
Operating rating:16.9 tons [15.4 metric tons]
Inventory rating:12.0 tons [10.9 metric tons]
Sufficiency rating:61.6
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$125,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
April 201761.6FairSatisfactorySatisfactorySatisfactory-25
April 201464.2FairSatisfactorySatisfactorySatisfactory-25
June 201339.0FairFairFairSatisfactorySD25
May 201239.0FairFairFairSatisfactorySD25
February 201039.0FairFairFairSatisfactorySD25
April 200838.7FairFairSatisfactorySatisfactorySD25
February 200638.7FairFairSatisfactorySatisfactorySD25
February 200438.7FairFairSatisfactorySatisfactorySD25
February 200238.7FairFairSatisfactorySatisfactorySD25
April 200038.7FairFairSatisfactorySatisfactorySD25
April 199838.7FairFairSatisfactorySatisfactorySD25
March 199638.7FairFairSatisfactorySatisfactorySD25
October 199334.0FairFairFairFairSD25
August 199134.0FairFairFairFairSD25