Share:

N. COUNTY LINE RD. over TRIB. TO WOLF CREEK

Map

Coordinates:
+39.13314, -98.73550
39°07'59" N, 98°44'08" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:N. COUNTY LINE RD. over TRIB. TO WOLF CREEK
Structure number:000840669304200
Location:1.0N 2.0W OF LURAY
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:16.1 ft. [4.9 m]
Total length:34.5 ft. [10.5 m]
Roadway width between curbs:27.2 ft. [8.3 m]
Deck width edge-to-edge:30.5 ft. [9.3 m]
Owner:County Highway Agency [02]
Year built:1937
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Number of main spans:2
Main spans material:Masonry [8]
Main spans design:Culvert [19]
Deck type:Not applicable [N]
Wearing surface:Gravel [8]

Latest Available Inspection: March 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:20 [as of 2008]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Operating rating:28.7 tons [26.1 metric tons]
Inventory rating:20.8 tons [18.9 metric tons]
Sufficiency rating:79.9

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
March 201679.9Fair6 out of 10-20
April 201479.9Fair6 out of 10-20
May 201279.9Fair6 out of 10-20
May 201079.9Fair6 out of 10-20
April 200879.9GoodN out of 10-20
February 200679.9GoodN out of 10-20
February 200479.9GoodN out of 10-20
February 200279.9GoodN out of 10-20
April 200079.8GoodN out of 10-20
April 199880.2GoodN out of 10-20
March 199679.8GoodN out of 10-20
October 199379.8GoodN out of 10-20
September 199179.8GoodN out of 10-20