Share:

RIDGE ROAD over BIG SLOUGH NORTH TRIB.

Map 

Coordinates:
+37.73047, -97.42624
37°43'50" N, 97°25'34" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:RIDGE ROAD over BIG SLOUGH NORTH TRIB.
Structure number:430400870000320
Location:RIDGE RD S. OF REFLECT RD
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:9.8 ft. [3.0 m]
Total length:21.3 ft. [6.5 m]
Owner:City or Municipal Highway Agency [04]
Year built:1997
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]
Wearing surface:Bituminous [6]

Latest Available Inspection: December 2015 

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:18,180 [as of 2006]
Truck traffic:2% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Pier/abutment protection:Navigation protection not required [1]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:51.9 tons [47.2 metric tons]
Inventory rating:30.9 tons [28.1 metric tons]
Sufficiency rating:76.7

Previous Inspections 

DateSuff. RatingConditionCulvert ConditionSD/FOADT
December 201576.7Good7 out of 10-18180
October 201376.7Good7 out of 10-18180
December 201172.4Good7 out of 10FO18180
November 200972.4Good7 out of 10FO18180
July 200772.4Good7 out of 10FO18180
December 200273.8Good7 out of 10-10425
February 200073.8Good8 out of 10-10425
February 199781.5Fair6 out of 10-9776
January 199582.4Fair6 out of 10-5588