Share:

WOMER over WICHITA VALLEY CTR FLDWY

Map 

Coordinates:
+37.74699, -97.36531
37°44'49" N, 97°21'55" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:WOMER over WICHITA VALLEY CTR FLDWY
Structure number:430400876351020
Location:womer S of 37th NORTH
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:58.1 ft. [17.7 m]
Total length:408.2 ft. [124.4 m]
Roadway width between curbs:52.5 ft. [16.0 m]
Deck width edge-to-edge:66.3 ft. [20.2 m]
Owner:City or Municipal Highway Agency [04]
Year built:1983
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:7
Main spans material:Prestressed concrete continuous [6]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: December 2015 

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:10,000 [as of 2006]
Truck traffic:2% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4]
Operating rating:46.9 tons [42.6 metric tons]
Inventory rating:40.9 tons [37.2 metric tons]
Sufficiency rating:80.1

Previous Inspections 

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
December 201580.1FairGoodVery GoodSatisfactory-10000
October 201380.1FairGoodVery GoodSatisfactory-10000
September 201180.1FairGoodVery GoodSatisfactory-10000
December 200980.1GoodGoodVery GoodVery Good-10000
July 200780.1GoodGoodVery GoodVery Good-10000
December 200280.2GoodGoodGoodGood-9435
February 200080.2GoodGoodGoodGood-9435
February 199780.1GoodGoodGoodGood-9838
January 199580.8GoodVery GoodVery GoodVery Good-7930
April 199378.0GoodExcellentExcellentExcellent-8935
May 199178.0GoodExcellentExcellentExcellent-8935