Share:

SENECA over TRIB TO WVCFLOODWAY

Map

Coordinates:
+37.59167, -97.35167
37°35'30" N, 97°21'06" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts

Name:SENECA over TRIB TO WVCFLOODWAY
Structure number:5304008700SSD20
Location:SENECA 500' S OF 55TH
Purpose:Carries highway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:6.9 ft. [2.1 m]
Total length:23.0 ft. [7.0 m]
Roadway width between curbs:47.9 ft. [14.6 m]
Deck width edge-to-edge:48.9 ft. [14.9 m]
Owner:City or Municipal Highway Agency [04]
Year built:1988
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]
Wearing surface:Bituminous [6]

Latest Available Inspection: December 2015

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:7,200 [as of 2006]
Truck traffic:2% of total traffic
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:35.0 tons [31.8 metric tons]
Inventory rating:21.0 tons [19.1 metric tons]
Sufficiency rating:59.0

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
December 201559.0Good7 out of 10FO7200
October 201359.0Good7 out of 10FO7200
September 201158.0Good7 out of 10FO7200
November 200958.0Good7 out of 10FO7200
July 200758.0Good7 out of 10FO7200
October 200378.0Good7 out of 10FO5503