Facts

Name:LINCOLN STREET over FABRIQUE BR. GYPSUM CK.
Structure number:530400870607020
Location:LINCOLN AT FABRIQUE
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:8.9 ft. [2.7 m]
Total length:29.9 ft. [9.1 m]
Owner:City or Municipal Highway Agency [04]
Year built:1952
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 18 / H 20 [4]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]
Wearing surface:Bituminous [6]

Latest Available Inspection: November 2015

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:11,500 [as of 2006]
Truck traffic:2% of total traffic
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:39.9 tons [36.3 metric tons]
Inventory rating:24.0 tons [21.8 metric tons]
Sufficiency rating:70.4

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
November 201570.4Good7 out of 10-11500
November 201370.4Good7 out of 10-11500
September 201166.2Good7 out of 10FO11500
November 200966.2Good7 out of 10FO11500
July 200766.2Good8 out of 10FO11500
November 200263.2Good7 out of 10FO11793
February 200063.1Good7 out of 10FO11793
March 199763.1Good8 out of 10FO11937
January 199562.4Good8 out of 10-12692
May 199370.7Good8 out of 10FO12692
May 199168.5Good8 out of 10FO22728