Share:

K-32 HIGHWAY over LITTLE TURKEY CR DRAIN

Map 

Coordinates:
+39.07370, -94.75701
39°04'25" N, 94°45'25" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:K-32 HIGHWAY over LITTLE TURKEY CR DRAIN
Structure number:999903201050921
Location:0.91 MILES E I-435
Purpose:Carries highway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:9.8 ft. [3.0 m]
Total length:27.2 ft. [8.3 m]
Skew angle:40°
Owner:State Highway Agency [01]
Year built:1928
Year reconstructed:1965
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: June 2015 

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:11,800 [as of 2014]
Truck traffic:11% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:48.5 tons [44.1 metric tons]
Inventory rating:29.0 tons [26.4 metric tons]
Sufficiency rating:80.2
Recommended work:Bridge deck replacement with only incidental widening. [37]
Estimated cost of work:$51,000

Previous Inspections 

DateSuff. RatingConditionCulvert ConditionSD/FOADT
June 201580.2Good7 out of 10-11800
June 201379.0Good7 out of 10-11800
May 201179.0Good7 out of 10-10300
May 200979.0Good7 out of 10-10500
June 200779.0Good7 out of 10-11100
June 200579.0Good7 out of 10-14100
June 200393.7Good7 out of 10-16500
September 200193.7Good7 out of 10-15870
November 199993.7Good7 out of 10-15550
August 199795.8Good7 out of 10-14660
April 199579.9Fair6 out of 10-15180
June 199379.9Good7 out of 10-16050
September 199152.0Good7 out of 10FO15490