Share:

I-635 SB HIGHWAY over STATE AVE

Map

Coordinates:
+39.11670, -94.68186
39°07'00" N, 94°40'55" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I-635 SB HIGHWAY over STATE AVE
Structure number:999963501050481
Location:I-635
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:91.9 ft. [28.0 m]
Total length:232.0 ft. [70.7 m]
Roadway width between curbs:66.3 ft. [20.2 m]
Deck width edge-to-edge:68.6 ft. [20.9 m]
Vertical clearance below bridge:17.1 ft. [5.2 m]
Skew angle:
Owner:State Highway Agency [01]
Year built:1968
Year reconstructed:2013
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:3
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Low slump Concrete [4]

Latest Available Inspection: June 2015

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:32,050 [as of 2014]
Truck traffic:5% of total traffic
Deck condition:Very Good [8 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Very Good [8 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Equal to present minimum criteria [6]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:69.9 tons [63.5 metric tons]
Inventory rating:41.9 tons [38.1 metric tons]
Sufficiency rating:90.9
Recommended work:Bridge deck replacement with only incidental widening. [37]
Estimated cost of work:$530,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
June 201590.9GoodVery GoodGoodVery Good-32050
June 201390.9GoodVery GoodGoodGood-32050
August 201191.0FairSatisfactoryGoodGood-30050
May 200991.1FairSatisfactoryGoodGood-29750
June 200790.9GoodGoodGoodGood-31750
June 200591.0GoodVery GoodGoodGood-30500
June 200384.9FairSatisfactoryGoodGoodFO29750
August 200184.8GoodGoodGoodGoodFO30500
October 199985.2GoodVery GoodGoodGoodFO27495
August 199785.2FairSatisfactoryVery GoodGoodFO27005
April 199586.9FairSatisfactorySatisfactoryGoodFO25305
June 199387.2FairSatisfactorySatisfactoryGoodFO21980
September 199186.8FairSatisfactoryGoodGoodFO22140

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.2,0292,029000
Steel Protective Coatingsq. ft.10,75310,753000
Deck
Reinforced Concrete Decksq. ft.15,35815,358000
Substructure
Reinforced Concrete Columneach88000
Reinforced Concrete Abutmentlinear ft.137137000
Reinforced Concrete Pier Caplinear ft.152152000
Bearings
Movable Bearingeach99000
Fixed Bearingeach99000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.464464000