Share:

SOUTH DANVILLE BYP over NS (CNO&TP) SYSTEM

Map

Coordinates:
+37.62167, -84.79439
37°37'18" N, 84°47'40" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SOUTH DANVILLE BYP over NS (CNO&TP) SYSTEM
Structure number:011B00038L
Location:.20 MI SOUTH OF JCT 37
Purpose:Carries highway over railroad
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:67.3 ft. [20.5 m]
Total length:507.9 ft. [154.8 m]
Roadway width between curbs:44.3 ft. [13.5 m]
Deck width edge-to-edge:47.9 ft. [14.6 m]
Vertical clearance below bridge:26.2 ft. [8.0 m]
Skew angle:
Owner:State Highway Agency [01]
Year built:1971
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:7
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: October 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:11,363 [as of 2015]
Truck traffic:5% of total traffic
Deck condition:Very Good [8 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Better than present minimum criteria [7]
Scour condition:Bridge not over waterway. [N]
Operating rating:59.8 tons [54.4 metric tons]
Inventory rating:30.9 tons [28.1 metric tons]
Sufficiency rating:84.5

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
October 201684.5FairVery GoodSatisfactoryFair-11363
October 201484.5FairFairFairFair-10753
October 201284.5FairFairFairFair-11400
October 201083.9FairFairFairFair-10500
October 200883.9FairFairFairFair-10700
August 200682.6FairFairFairFair-21800
October 200482.5FairFairSatisfactoryFair-23067

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.3,0722,80402680
Deck
Reinforced Concrete Decksq. ft.23,91621,6651,4358160
Wearing Surfacessq. ft.22,37620,2171,3438160
Substructure
Reinforced Concrete Columneach1814130
Reinforced Concrete Abutmentlinear ft.138488460
Reinforced Concrete Pier Caplinear ft.276151171080
Joints
Pourable Jointlinear ft.376000376
Bearings
Movable Bearingeach8400840
Steel Protective Coatingsq. ft.168001680
Bridge Rail
Other Material Bridge Raillinear ft.1,0241,0120120