KY-8 over FOUR MILE CREEK
Map
Coordinates:
+39.04389, -84.4200039°02'38" N, 84°25'12" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | KY-8 over FOUR MILE CREEK |
Structure number: | 019B00004N |
Old structure number: | 019*0008*B0004 (from 1992 edition) |
Location: | 300FT SOU. OF JCT KY 1998 |
Purpose: | Carries highway over waterway |
Route classification: | Minor Arterial (Urban) [16] |
Length of largest span: | 17.1 ft. [5.2 m] |
Total length: | 38.1 ft. [11.6 m] |
Skew angle: | 45° |
Owner: | State Highway Agency [01] |
Year built: | 1951 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 18 / H 20 [4] |
Number of main spans: | 2 |
Main spans material: | Concrete [1] |
Main spans design: | Culvert [19] |
Deck type: | Not applicable [N] |
Latest Available Inspection: August 2017
Good/Fair/Poor Condition: | Fair |
Status: | Posted for load [P] |
Average daily traffic: | 7,410 [as of 2016] |
Truck traffic: | 8% of total traffic |
Structural appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Better than present minimum criteria [7] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Culvert condition: | Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 72.3 |
Previous Inspections
Date | Condition | Culvert Condition | ADT | Suff. Rating |
---|
August 2017 | Fair | 6 out of 10 | 7410 | 72.3 |
August 2015 | Fair | 6 out of 10 | 7041 | 72.7 |
August 2013 | Fair | 6 out of 10 | 7041 | 72.7 |
August 2011 | Fair | 6 out of 10 | 7720 | 71.9 |
February 2010 | Fair | 6 out of 10 | 8290 | 71.3 |
April 2008 | Fair | 6 out of 10 | 8380 | 71.2 |
January 2008 | Fair | 6 out of 10 | 8380 | 71.2 |
October 2005 | Fair | 6 out of 10 | 7890 | 71.8 |
November 2003 | Fair | 6 out of 10 | 5612 | 83.4 |
September 2001 | Fair | 5 out of 10 | 5612 | 70.6 |
July 1999 | Fair | 5 out of 10 | 5612 | 70.6 |
September 1997 | Fair | 5 out of 10 | 5612 | 70.6 |
September 1995 | Fair | 5 out of 10 | 8474 | 75.7 |
October 1993 | Fair | 6 out of 10 | 8474 | 86.7 |
August 1991 | Fair | 6 out of 10 | 8474 | 86.7 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Culvert |
Reinforced Concrete Culvert | linear ft. | 412 | 322 | 20 | 70 | 0 |