Share:

I-275 EB over OHIO RIVER @ BRENT

Map

Coordinates:
+39.05694, -84.43056
39°03'25" N, 84°25'50" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I-275 EB over OHIO RIVER @ BRENT
Structure number:019B00040R
Old structure number:019*0275*B0040P (from 1992 edition)
Location:EBL OVER OHIO
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:720.2 ft. [219.5 m]
Total length:1441.0 ft. [439.2 m]
Roadway width between curbs:51.2 ft. [15.6 m]
Deck width edge-to-edge:55.1 ft. [16.8 m]
Vertical clearance above deck:18.0 ft. [5.5 m]
Vertical clearance below bridge:95.1 ft. [29.0 m]
Owner:State Highway Agency [01]
Year built:1979
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Steel [3]
Main spans design:Truss - Thru [10]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: October 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:41,219 [as of 2015]
Truck traffic:5% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:91.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2016FairFairSatisfactorySatisfactory4121991.0
October 2014FairFairSatisfactorySatisfactory3718691.0
September 2013FairFairSatisfactorySatisfactory4265391.0
October 2012FairFairSatisfactorySatisfactory4210091.0
October 2010FairFairSatisfactoryGood3650087.5
September 2009FairFairSatisfactoryGood3920087.2
January 2009----4140088.1
November 2006FairSatisfactorySatisfactoryGood8280084.1
October 2005GoodGoodGoodGood7877085.6
October 2003GoodGoodGoodGood3164691.0
October 2001GoodGoodGoodVery Good3164689.0
October 2000GoodGoodGoodVery Good3164689.0
October 1998GoodGoodGoodVery Good3164689.0
October 1996GoodGoodGoodVery Good3164689.0
October 1995GoodGoodGoodVery Good3164689.6
October 1993FairSatisfactorySatisfactoryFair3164678.2
October 1992GoodVery GoodVery GoodVery Good2048290.4
October 1991GoodVery GoodVery GoodVery Good2048290.4

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Stringerlinear ft.10,0807,0562,5205040
Steel Protective Coatingsq. ft.82,55515,68561,9164,128826
Deck
Reinforced Concrete Decksq. ft.79,25571,2557,0001,0000
Wearing Surfacessq. ft.73,851073,1517000
Superstructure
Steel Trusslinear ft.2,8821,4411,1213200
Steel Protective Coatingsq. ft.124,5510110,85012,4551,246
Steel Floor Beamlinear ft.1,8379176702500
Steel Protective Coatingsq. ft.43,6108,72210,90215,2648,722
Steel Gusset Plateeach138091470
Steel Protective Coatingsq. ft.10,3741,9717,780519104
Substructure
Reinforced Concrete Columneach60420
Reinforced Concrete Pile Cap/Footinglinear ft.122122000
Joints
Compression Jointlinear ft.3604302504
Assembly with Sealeach1030751216
Bearings
Movable Bearingeach40400
Steel Protective Coatingsq. ft.2690242270
Fixed Bearingeach20110
Steel Protective Coatingsq. ft.2550230250
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.2,8822,59428800