Name:SHAW GOETZ RD over TWELVEMILE CREEK
Structure number:019C00012N
Location:75' S OF JCT CR 5122
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:27.9 ft. [8.5 m]
Total length:84.0 ft. [25.6 m]
Roadway width between curbs:24.3 ft. [7.4 m]
Deck width edge-to-edge:28.2 ft. [8.6 m]
Owner:County Highway Agency [02]
Year built:1957
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: January 2016

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:586 [as of 2006]
Deck condition:Fair [5 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:84.7

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
January 2016FairFairSatisfactorySatisfactory58684.7
January 2015FairFairSatisfactorySatisfactory58684.7
January 2014FairFairSatisfactorySatisfactory58684.7
January 2013FairFairSatisfactorySatisfactory58656.0
January 2012FairFairSatisfactorySatisfactory58656.0
January 2011FairFairSatisfactorySatisfactory58656.0
February 2010FairFairSatisfactorySatisfactory58656.0
February 2009FairFairSatisfactorySatisfactory58656.0
April 2007FairFairFairSatisfactory54948.9
February 2006FairFairFairSatisfactory20051.8

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.3343141640
Deck
Reinforced Concrete Top Flangesq. ft.2,3701,96740300
Wearing Surfacessq. ft.2,0442,044000
Substructure
Reinforced Concrete Columneach44000
Reinforced Concrete Abutmentlinear ft.60164400
Reinforced Concrete Pier Caplinear ft.4742500
Joints
Open Jointlinear ft.4000400
Bearings
Enclosed/Concealed Bearingeach2424000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.1641541000