Share:

CS-1108A over NORTH FORK LITTLE RIVER

Map

Coordinates:
+36.86722, -87.48972
36°52'02" N, 87°29'23" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:CS-1108A over NORTH FORK LITTLE RIVER
Structure number:024C00082N
Location:200" WEST OF BETHEL ST.
Purpose:Carries highway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:37.1 ft. [11.3 m]
Total length:137.1 ft. [41.8 m]
Roadway width between curbs:25.6 ft. [7.8 m]
Deck width edge-to-edge:34.1 ft. [10.4 m]
Owner:City or Municipal Highway Agency [04]
Year built:1904
Year reconstructed:2003
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Masonry [8]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: August 2018

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:4,613 [as of 2012]
Truck traffic:7% of total traffic
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Moderate to major deterioration or disintegration, extensive cracking and leaching or spalls on concrete or masonry walls and slabs. Minor settlement or misalignment. Noticeable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection in one section, significant corrosion or deep pitting. [5]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:42.5

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
August 2018Fair5 out of 10461342.5
August 2017Fair5 out of 10461342.5
August 2016Fair5 out of 10461342.5
August 2015Fair5 out of 10461342.5
August 2014Fair5 out of 10425142.5
August 2013Fair5 out of 10461342.5
August 2012Fair5 out of 10376042.5
August 2011Fair5 out of 10390042.5
August 2010Fair5 out of 10409042.5
August 2009Fair5 out of 10392042.5
August 2007Fair5 out of 10332041.5
June 2005Fair5 out of 10456041.2

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Deck
Reinforced Concrete Decksq. ft.4,6634,3132001500
Superstructure
Masonry Archlinear ft.66392070
Substructure
Masonry Pier Walllinear ft.3303300
Masonry Abutmentlinear ft.6606600
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.273027300
Steel Protective Coatingsq. ft.54444410000