KY-415 over SMITH CREEK
Map
Coordinates:
+36.69306, -85.0922236°41'35" N, 85°05'32" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | KY-415 over SMITH CREEK |
Structure number: | 027B00029N |
Old structure number: | 027*0415*B0029 (from 1992 edition) |
Location: | .40 MI SE JCT KY 350 |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 70.9 ft. [21.6 m] |
Total length: | 73.2 ft. [22.3 m] |
Roadway width between curbs: | 24.0 ft. [7.3 m] |
Deck width edge-to-edge: | 28.5 ft. [8.7 m] |
Skew angle: | 45° |
Owner: | State Highway Agency [01] |
Year built: | 1985 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Main span material: | Prestressed concrete [5] |
Main span design: | Box beam or girders - Multiple [05] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: December 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 216 [as of 2015] |
Truck traffic: | 7% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 82.3 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
December 2017 | Fair | Fair | Fair | Satisfactory | 216 | 82.3 |
December 2015 | Fair | Fair | Fair | Satisfactory | 261 | 77.8 |
December 2013 | Fair | Fair | Fair | Good | 239 | 82.3 |
December 2011 | Fair | Satisfactory | Satisfactory | Good | 209 | 94.4 |
December 2009 | Fair | Satisfactory | Satisfactory | Good | 205 | 94.4 |
December 2007 | Fair | Satisfactory | Satisfactory | Good | 199 | 94.4 |
December 2005 | Fair | Satisfactory | Satisfactory | Good | 195 | 94.4 |
December 2003 | Fair | Satisfactory | Satisfactory | Good | 191 | 94.4 |
December 2001 | Fair | Satisfactory | Satisfactory | Good | 191 | 94.4 |
December 1999 | Fair | Satisfactory | Satisfactory | Good | 191 | 94.4 |
December 1997 | Fair | Satisfactory | Satisfactory | Good | 191 | 94.4 |
December 1995 | Fair | Satisfactory | Good | Good | 239 | 91.3 |
December 1993 | Fair | Satisfactory | Very Good | Good | 239 | 91.3 |
December 1991 | Good | Good | Very Good | Very Good | 239 | 91.3 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Closed Web/Box Girder | linear ft. | 490 | 184 | 247 | 57 | 2 |
Deck |
Prestressed Concrete Top Flange | sq. ft. | 2,088 | 1,278 | 800 | 10 | 0 |
Wearing Surfaces | sq. ft. | 1,869 | 1,059 | 800 | 10 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 100 | 69 | 31 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 16 | 16 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 140 | 140 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 420 | 420 | 0 | 0 | 0 |
Reinforced Concrete Bridge Rail | linear ft. | 140 | 140 | 0 | 0 | 0 |