KY-7 over DOCTORS BRANCH
Map
Coordinates:
+38.06778, -83.1661138°04'04" N, 83°09'58" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | KY-7 over DOCTORS BRANCH |
Structure number: | 032B00007N |
Old structure number: | 032*0007*B0007 (from 1992 edition) |
Location: | .60 MI WEST OF JCT KY 650 |
Purpose: | Carries highway over waterway |
Route classification: | Minor Arterial (Rural) [06] |
Length of largest span: | 24.9 ft. [7.6 m] |
Total length: | 56.1 ft. [17.1 m] |
Roadway width between curbs: | 24.0 ft. [7.3 m] |
Deck width edge-to-edge: | 27.9 ft. [8.5 m] |
Skew angle: | 45° |
Owner: | State Highway Agency [01] |
Year built: | 1937 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 13.5 / H 15 [2] |
Number of main spans: | 2 |
Main spans material: | Concrete [1] |
Main spans design: | Tee beam [04] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: August 2017
Good/Fair/Poor Condition: | Fair |
Status: | Posted for load [P] |
Average daily traffic: | 1,606 [as of 2016] |
Truck traffic: | 11% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Better than present minimum criteria [7] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 68.2 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2017 | Fair | Fair | Fair | Satisfactory | 1606 | 68.2 |
August 2015 | Fair | Fair | Satisfactory | Satisfactory | 1474 | 79.6 |
August 2013 | Fair | Fair | Satisfactory | Satisfactory | 1474 | 79.6 |
August 2011 | Fair | Fair | Satisfactory | Satisfactory | 1950 | 79.1 |
August 2009 | Fair | Fair | Satisfactory | Satisfactory | 1790 | 79.3 |
August 2007 | Fair | Fair | Good | Satisfactory | 1730 | 79.4 |
August 2005 | Fair | Fair | Good | Satisfactory | 1896 | 79.2 |
July 2003 | Fair | Fair | Good | Good | 1990 | 79.1 |
September 1999 | Fair | Fair | Good | Good | 1990 | 78.1 |
October 1997 | Fair | Fair | Good | Good | 1990 | 78.1 |
August 1995 | Fair | Fair | Good | Good | 2065 | 73.0 |
August 1993 | Fair | Satisfactory | Good | Good | 2065 | 74.0 |
August 1991 | Fair | Satisfactory | Satisfactory | Good | 2065 | 74.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 280 | 266 | 13 | 1 | 0 |
Deck |
Reinforced Concrete Top Flange | sq. ft. | 1,571 | 1,196 | 300 | 75 | 0 |
Wearing Surfaces | sq. ft. | 1,349 | 0 | 1,307 | 42 | 0 |
Substructure |
Reinforced Concrete Column | each | 3 | 0 | 3 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 140 | 133 | 7 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 42 | 36 | 6 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 108 | 0 | 70 | 38 | 0 |