Share:

CR-1223 over WELLS CREEK

Map

Coordinates:
+38.04972, -83.15500
38°02'59" N, 83°09'18" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:CR-1223 over WELLS CREEK
Structure number:032C00018N
Location:.1 MI E OF JCT KY 650
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:23.0 ft. [7.0 m]
Total length:24.9 ft. [7.6 m]
Roadway width between curbs:9.8 ft. [3.0 m]
Deck width edge-to-edge:11.2 ft. [3.4 m]
Skew angle:15°
Owner:County Highway Agency [02]
Year built:1970
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: December 2018

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:20 [as of 2009]
Truck traffic:11% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Basically intolerable requiring high priority of replacement [2]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:35.3
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$39,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
December 2018FairGoodSatisfactorySatisfactory2035.3
December 2017FairGoodSatisfactorySatisfactory1035.7
December 2016FairGoodSatisfactorySatisfactory1035.7
December 2015FairGoodSatisfactorySatisfactory1035.7
December 2014FairGoodSatisfactorySatisfactory1035.7
December 2013FairGoodSatisfactorySatisfactory1035.8
December 2012FairGoodSatisfactorySatisfactory1035.8
December 2011FairGoodSatisfactorySatisfactory1035.8
December 2010FairGoodSatisfactorySatisfactory1035.8
December 2009FairGoodSatisfactorySatisfactory1035.8
December 2008FairGoodSatisfactorySatisfactory1035.8
December 2007FairGoodSatisfactorySatisfactory1042.3
December 2004FairFairSatisfactorySatisfactory741.3

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.125012500
Steel Protective Coatingsq. ft.31802180100
Deck
Reinforced Concrete Decksq. ft.2742621200
Substructure
Reinforced Concrete Abutmentlinear ft.6559060
Reinforced Concrete Pile Cap/Footinglinear ft.3232000