GALLION BR RD over BLAINE TRACE
Map
Coordinates:
+38.13056, -82.9252838°07'50" N, 82°55'31" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | GALLION BR RD over BLAINE TRACE |
Structure number: | 032C00027N |
Location: | .1 MI W JCT CR 5014 |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 37.1 ft. [11.3 m] |
Total length: | 40.0 ft. [12.2 m] |
Roadway width between curbs: | 14.4 ft. [4.4 m] |
Deck width edge-to-edge: | 16.1 ft. [4.9 m] |
Owner: | County Highway Agency [02] |
Year built: | 1991 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 22.5 / HS 25 [9] |
Main span material: | Prestressed concrete [5] |
Main span design: | Box beam or girders - Multiple [05] |
Deck type: | Concrete Precast Panels [2] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: December 2018
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 110 [as of 2009] |
Truck traffic: | 11% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Countermeasures have been installed to mitigate an existing problem with scour. [7] |
Sufficiency rating: | 74.2 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
December 2018 | Good | Good | Good | Good | 110 | 74.2 |
December 2016 | Good | Good | Good | Good | 35 | 78.9 |
December 2014 | Good | Good | Good | Good | 35 | 78.9 |
December 2012 | Good | Good | Good | Good | 35 | 78.9 |
December 2010 | Good | Good | Good | Good | 35 | 78.9 |
December 2008 | Good | Good | Good | Good | 35 | 78.9 |
November 2006 | Good | Good | Good | Good | 75 | 78.6 |
December 2004 | Good | Good | Good | Good | 28 | 79.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Closed Web/Box Girder | linear ft. | 160 | 156 | 4 | 0 | 0 |
Deck |
Prestressed Concrete Top Flange | sq. ft. | 643 | 635 | 8 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 78 | 78 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 76 | 76 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 498 | 0 | 498 | 0 | 0 |